Article No
MIL10
Housing
- 10 x 15 x 45.5 mm
- Sensor head
Baumer
Linear magnetic encoders
MIL10 Incremental linear encoder
Baumer MIL10 features 20‑fold / 50‑fold / 100‑fold interpolation, index signal / width 90° reference signal, EN 61000-6-4 emitted interference, ≤ 50 ms (power after power on) initializing time and 40…60 % duty cycle.
Technical Specifications
Article No
MIL10
Housing
- 10 x 15 x 45.5 mm
- Sensor head
Product Description
System for linear motion feedback. Magnetic strip sensor head, incremental output signals (HTL/push-pull and TTL/RS422), resolution down to 5 µm. Contactless, wear-free sensing, high resistance to dirt and vibration. Configurable product — see configuration options for the order code.
Configure the Product
Create your own order code by selecting the options below.
Connection
Voltage supply / Output
Interpolation / Resolution
Type: [S] Sensor head
Kutup aralığı: [2] 2 mm
Reference signal: [P] İndeks sinyali (kutup periyodik)
Operating temperature: [A] -40...+85 °C
Order Code
Detailed Technical Data
General data
Approval
- CE
- UL
Interpolation
- 20‑fold
- 50‑fold
- 100‑fold
Resolution
- 5 µm (4-times evaluation)
- 10 µm (4-times evaluation)
- 25 µm (4-times evaluation)
Reference signal
Index signal, width 90°
Emitted interference
EN 61000-6-4
Start-up time
≤ 50 ms (power after power on)
Duty cycle
40…60 %
Detection method
Magnetic
System accuracy
±(0.02 mm + 0.04 mm x magnetic tape length (m))
Output stages
- HTL/push-pull
- TTL/RS422
Output frequency
≤350 kHz
Output signals
A+, B+, R+, A-, B-, R-
Short-circuit protected
Yes
Interference immunity
EN 61000-6-2
Mechanical Data
Resistance
- EN 60068-2-6
- Vibration 30 g, 10-2000 Hz
- EN 60068-2-27
- Shock 500 g, 6 ms
Material
Enclosure: die-cast zinc, coated
Connection
- Cable 2 m
- Cable 0.3 m with connector M12
Relative humidity
- EN 60068-2-78:2010
- EN 60068-2-30:2005
- 93 % condensation permitted
Travel speed
- <5 m/s (resolution 5 µm)
- <10 m/s (resolution 10 µm)
- <25 m/s (resolution 25 µm)
Protection EN 60529
- IP 66
- IP 67
Operating distance
0.1 … 0.6 mm
Weight (approx.)
130 g
Operating temperature
-40...+85 °C
Dimensions (sensor head)
10 x 15 x 45.5 mm
Ambient conditions
Relative humidity
EN 60068-2-78:2010, EN 60068-2-30:2005, %93 condensation permitted
Durability
EN 60068-2-6 Vibration 30 g, 10-2000 Hz; EN 60068-2-27 Shock 500 g, 6 ms
Operating temperature
-40...+85 °C
Electrical data (HTL)
Voltage supply
10...30 VDC
Consumption (typical)
20 mA (unloaded)
Reverse polarity protection
Yes
Electrical data (TTL)
Voltage supply
5 VDC ±5 %
Consumption (typical)
30 mA (unloaded)
Recommended cable termination
120 Ohm per channel pair on control side
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_Mxx_10_ML_DoC_81159607.pdf