Baumer optoPulse EXEIL580P-BT12.5BF.01024.F/0122
Article No 11190100
Dimension (flange) ø58 mm
Shaft Type ø12 mm (blind hollow shaft)
Baumer Industrial incremental encoders

optoPulse EXEIL580P-BT12.5BF.01024.F/0122 Incremental encoder

Baumer optoPulse EXEIL580P-BT12.5BF.01024.F/0122 features ø48…59 mm size, blind hollow shaft, 1024 … 2047 pulses, optical sensing method and IP 65 protection EN 60529.

Series: EIL580P — 58 mm – blind hollow shaft →

Technical Specifications

Article No 11190100
Dimension (flange) ø58 mm
Shaft Type ø12 mm (blind hollow shaft)
Product Description
  • Size ø58 mm
  • Precise optical sensing (interpolated)
  • Output signal level programmable (TTL pre-programmed)
  • Blind hollow shaft, ø12 mm
  • Flange connector M12, 8-pin CCW, radial
  • Pulses per revolution 1...65536, programmable
  • High resistance to shock and vibrations
  • Option 0122, Explosion protection zone 22

Detailed Technical Data

Technical Data - Mechanical Design

Resistance
  • EN 60068-2-6
  • Vibration 30 g, 10-2000 Hz
  • EN 60068-2-27
  • Shock 250 g, 6 ms
Material
  • Housing: aluminium die-cast
  • Flange: aluminium
Shaft type ø12 mm (blind recessed mil)
Connection Flange connector M12, 8-pin
Relative humidity 90 % non-condensing
Dimension (flange) ø58 mm
Starting torque ≤0.02 Nm (+20 °C, IP 65)
Protection EN 60529 IP 65
Operating speed
  • ≤8000 rpm (+20 °C)
  • ≤8000 rpm (+40 °C)
  • ≤5000 rpm (+60 °C)
Ambient temperature -20...+60 °C
Approximate weight 300 g
Explosion protection II 3 D Ex tc IIIC T135°C Dc X (dust): see special conditions “X”

Technical Data - Electrical Values

Supply voltage 4.75...30 VDC
Reference signal Zero pulse, width 90° ±10 %
Emitted interference EN 61000-6-3
Start-up time ≤ 30 ms after power on
Consumption w/o load ≤70 mA
Duty cycle 45…55 % typical at 1024, 2048 ppr (further see table Duty cycle)
Detection method Optical
Output stages
  • TTL/RS422
  • HTL/push-pull
Output frequency
  • ≤300 kHz (TTL)
  • ≤160 kHz (HTL)
Output signals A+, B+, R+, A-, B-, R-
Short-circuit protected Yes
Reverse polarity protection Yes
Interference immunity EN 61000-6-2
Pulses per revolution 1024
Programmable parameters
  • Output level TTL/HTL
  • Pulse number 1...65536
  • Zero pulse width 90°/180°
  • Zero pulse position
  • Signal sequence

Documents

description Data sheet PDF · Baumer_EXEIL580P-BT12.5BF.01024.F-0122_EN_20251209_DS.pdf open_in_new Open
build Installation instructions PDF · Baumer_ExEIL580P_II_DE-EN_2408_11261377_web.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_ExEIL580_ML_DoC_81203354.pdf open_in_new Open
view_in_ar CAD data ZIP · Baumer_EIL580-BT12.5Bx.xxxxx_.A-stp_CAD.zip open_in_new Open
download Software ZIP · Baumer_Encoder-Software-V33-16-07-05_SW_EN_1607.zip open_in_new Open
auto_stories Brochure PDF · Baumer_EIL580P_BR_EN_1807_11202890_LRes.pdf open_in_new Open
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3