Article No
11250441
Measurement Principle
Inductive
Process Pressure
≤ 25 bar
Baumer
Liquid analysis
PAC50H-1430A.32D11E.A04304.1030 Conductivity sensor
Baumer PAC50H-1430A.32D11E.A04304.1030 features ≤ 25 bar process pressure, inductive measuring principle and PEEK Natura wetted parts material.
Technical Specifications
Article No
11250441
Measurement Principle
Inductive
Process Pressure
≤ 25 bar
Process Temperature (Continuous)
-25...140°C
Product Description
- Precision measurements with 2% accuracy
- Short response time (15 s)
- Ideal for media detection and differentiation
- Wetted parts in PEEK
- IO-Link Dual Channel for easy commissioning
Detailed Technical Data
IO-LINK INTERFACE
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
Device profile
Smart Sensor Profile
Cycle time
≥ 14 ms
IO-Link version
1.1
Process data length
128 bit
Process data (cyclic)
- Switch state
- State of alert
- Unit temperature
- Analog output
- Process temperature
- Conductivity
- Concentration
- Actual measuring range
PROCESS CONDITIONS
Process pressure
≤ 25 bar
Process temperature
- -25 … 140 °C , permanent
- 140 … 150 °C , max. t < 1 h
- SIP/CIP compatibility
Ambient conditions
Protection degree (EN 60529)
- IP65
- IP67
- IP69K , with appropriate cable
Process connection
Wetted parts material
PEEK Natura
Connection variants
G 1 A hygienic
Wetted part surface roughness
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
EMC
- EN 61326-1
- DNV
Hygiene
- 3-A (74-07)
- EHEDG EL Class I
- FDA (21 CFR 177.2415)
Performance Features - Temperature
Measuring range
-25 … 150 °C
Max. measurement error
- ± 1.5 K
- ± 0.3 K , 20 … 50 °C
Thermal response time, T90
≤ 15 s
Performance Features - Conductivity
Repeatability
≤ ± 1.0 % MV ± 10 µS/cm
Sampling time
≤ 0.4 s
Reference temperature
25 °C , adjustable
Max. measurement error
≤ ± 2.0 % MV ± 15 µS/cm
Temperature compensated
0.0 … 5.0 %/K , adjustable
Step response time, T90
≤ 1.5 s
Min. measurable conductivity
1 µS/cm
Max. measuring range width
1000 mS/cm
Compensated temperature range
-20 … 150 °C
Performance Features - Concentration
Concentration
IO-Link and FlexProgram with programmable
Input damping
0 … 30 s , programmable
Customer defined media
Customer defined (30 point lookup table)
Factory set media (available from FlexProgram)
- 0 … 25 % by weight , HNO3 (nitric acid)
- 36 … 82 % by weight , HNO3 (nitric acid)
- 0 … 12 % by weight , NaOH (caustic soda)
- 25 … 50 % by weight , NaOH (caustic soda)
Documents
menu_book
Operating manual
PDF · Baumer_PAC50x_IODD_Parameter_and_Process_Data_MA_EN_1808.pdf
open_in_new Open
verified_user
Declaration of Conformity – CE
PDF · Baumer_PAC50x_ML_DoC_81388107.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – MTTF
PDF · MTTF_PAC50SH-xxxxx.xxxx1x.xxxxxx.xxxx_.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_PAC50x_CoC_81439253.pdf
open_in_new Open
restaurant
Food Regulatory Declaration of Conformity
PDF · Baumer_PAC50H_DE_EN-FR_FRDoC_81388108.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – 3-A
PDF · Baumer_3-A_certificate_930_EN_CoC_81082191.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_AFIx+PAC50H_EN_CoC_81153821.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_PAC50_EN_RoC_81414149.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – MTTF
PDF · MTTF_PAC50S(H)-xxxxx.xxxx1x.xxxxxx.xxxx.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – MTTF
PDF · MTTF_PAC50S(H)-xxxxx.xxxx0x.xxxxxx.xxxx.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11250441
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Definitions of Sensor Properties_V1.1_EN.pdf
open_in_new Open