Article No
11251394
Measurement Range
-1 … 2 bar
Initial Accuracy
≤ 0.1 % FS
Baumer
Pressure sensors
PBMH-25B75RA11453522010 Pressure sensor
Baumer PBMH-25B75RA11453522010 features very low (up to 2 bar) pressure range, relative (gauge) pressure type and ISO 2852 (Tri-Clamp) / DN 25 / Ø 50.5 (C03) process connection.
Technical Specifications
Article No
11251394
Measurement Range
-1 … 2 bar
Initial Accuracy
≤ 0.1 % FS
Process Connection
ISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (C03)
Product Description
- 3-A sanitary standards, FDA-compliant, EHEDG-certified
- Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
- Versions available for high media temperatures (200 °C)
- Surface roughness connection Ra ≤ 0.8 for highest hygienic requirements
- Fully welded and compact design for washdowns without residuals
- Excellent active temperature compensation for increased process stability
- External programming of zero point and span with FlexProgrammer 9701
- Absolute pressure, relative pressure and vacuum measurement
Detailed Technical Data
Process connection
Connection variants
ISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (BCID: C03)
Wet part material, membrane
AISI 316L (1.4435)
COMPLIANCE AND APPROVALS
Explosion protection
- ATEX II 1D Ex ia IIIC T (200) 107 °C IP6X Da
- ATEX II 1G Ex ia IIC T4/T6 Ga
Performance characteristics
Pressure type
Relative (gauged)
Measuring range
-1 … 2 bar
Max. turndown ratio
5 : 1
Max. measurement error
- ± 0.1 % FSR
- Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
Temperature coefficient
- ≤ 0.03 % FSR/10 K , measuring span
- ≤ 0.03 % FSR/10 K , zero point
Long-term stability
≤ 0.1 % FSR/a , measuring range > 1 bar
Rise time (%10 … %90)
≤ 5 ms
Standard error of measurement (BFSL)
- ± 0.04 % FSR
- Including non-linearity, hysteresis and non-repeatability according BFSL
Compensated temperature range
-40 … 85 °C
Documents
rocket_launch
Quick start guide
ZIP · Baumer_Kurzanleitung_PBMH-EX_DE-EN-FR_81205574_V2.zip
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_PxMx_DE-EN-FR_CoC_81164152.pdf
open_in_new Open
restaurant
Food Regulatory Declaration of Harmlessness
PDF · Baumer_PBMH_DE-EN-FR_FRDoH_81152897.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – ATEX / UKEX
PDF · Baumer_PxMx_EN_RoC_81164171_ATEX.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – IECEx
PDF · Baumer_PxMx_EN_RoC_81394588_IECEX.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – ATEX / UKEX
PDF · Baumer_PxMx_EN_RoC_81398299_UKEX.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_PBMH_PP20H_EN_CoC_81158269.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – 3-A
PDF · Baumer_3-A_PBMH_PP20H_2025.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Analog_Sensor_Interfaces_Guideline_V1.00_EN.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Explosion_Protection_Guideline_(ATEX)_V1.40_EN.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Definitions of Sensor Properties_V1.1_EN.pdf
open_in_new Open