Article No
11265331
Measurement Technology
Capacitive level switches
Function
Point level detection
Baumer
Level sensors
PL240-140T54.WV0020.00 Capacitive proximity sensors
Baumer PL240-140T54.WV0020.00 features capacitive level switches measuring technology, adhesion compensation special type and flush with the outer wall of the vessel mounting type.
Technical Specifications
Article No
11265331
Measurement Technology
Capacitive level switches
Function
Point level detection
Features
Features / Push-pull / Ready-wired connector M12, L=200 mm-25 … 60 °CIP 67
Product Description
- Detection of water-based liquids
- For container walls made of plastic or glass up to 6 mm
- Foam and adhesion compensation
- Air gaps of up to 1 mm between tank and sensor
- High immunity to humidity and moisture
Detailed Technical Data
General Data
Special type
Adhesion compensation
Mounting type
Flush with the outer wall of the vessel
Measurement type
Contactless
Sensitivity setting
Teach-in: remote
Output indicator
Yellow LED
Power-on indicator
Green LED
Nominal sensing range Sn
6 mm
Nominal sensing range Sn adjustable
0.5 … 6 mm
Application Area
Liquids in direct contact
No
Object detection / bulk material
No
Detection of non-conductive media
Yes (water-based liquids)
Fill level detection through container
Yes
Mechanical Data
Dimension
40 mm
Depth
10 mm
Design
Rectangle
Housing material
PP/PA
Housing length
40 mm
Connection types
Coiled connector M12, L=200 mm
Ambient conditions
Protection class
IP 67
Storage temperature
-40 … +80 °C
Vibration (sinusoidal)
- IEC 60068-2-6:2008
- 1 mm p-p at f = 10 - 55 Hz, duration 5 min per axis
- 30 min endurance at f = 55 Hz per axis
Operating temperature
-25 … +60 °C
Shock (half-sinusoidal)
- IEC 60068-2-27:2009
- 30 g / 11 ms, 6 jolts per axis and direction
Electrical Data
Output current
≤50 mA
Output circuit
Push-pull
Switching frequency
5 Hz
Short-circuit protection
Yes
Voltage drop Vd
<3 VDC
Reverse polarity protection
Yes
Supply voltage range +Vs
10 … 30 VDC
Max. current consumption (no load)
70 mA
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_PL240_ML_DoC_81437082.pdf
open_in_new Open