Shaft Type
ø115 mm
Baumer
Bearingless encoders
PMG10 - Incremental Incremental encoder
Baumer PMG10 - Incremental features ø100…160 mm size, straight shaft, incremental interface, ≥ 36000 pulses and magnetic sensing method.
Series: HMG10P — Configurable rotary encoder with speed switch →
Technical Specifications
Shaft Type
ø115 mm
Product Description
- Incremental encoder (optionally programmable)
- HTL/TTL output driver for cable length up to 350 m
- Very high resistance to shock and vibrations
- Two-sided insulated bearing system with hybrid bearings
- Special protection against corrosion CX (C5-M)
- Large terminal box, turn by 180°
- Function display via LEDs
Detailed Technical Data
Technical Data - Mechanical Design
Flange
- EURO flange B10
- Housing foot B3
Resistance
- IEC 60068-2-6
- Vibration 30 g, 10-2000 Hz
- IEC 60068-2-27
- Shock 400 g, 1 ms
Material
- Housing: aluminium alloy
- Shaft: stainless steel
Shaft type
ø11 mm full mil
Connection
- Terminal box
- Flange connector M23
Relative humidity
95 % non-condensing
Dimension (flange)
ø115 mm
Protection EN 60529
IP 66 / IP 67
Operating speed
≤12000 rpm
Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions CX (C5-M) according to ISO 12944-2
Approximate weight
1.9 kg (depending on version)
Operating temperature
-40...+95 °C
Operating torque (typical)
10 Ncm
Permissible shaft load
- ≤450 N axial
- ≤650 N radial
Rotor moment of inertia
1 kgcm²
Switching speed range
ns (off) = ±2...12000 rpm, factory setting 6000 rpm
Technical Data - Electrical Values
Approval
- CE
- UL approval / E217823
Phase shift
90 ° ±20°
Supply voltage
4.75...30 VDC
Reference signal
Zero pulse, width 90°
Emitted interference
EN 61000-6-3
Start-up time
power after power on ≤ 500 ms
Status indicator
4 LEDs in device back side
Consumption w/o load
≤100 mA
Duty cycle
40…60 %
Detection method
Magnetic
Diagnostic function
Function check
Output stages
HTL/TTL (Vin = Vout)
Output signals
- A+, B+, R+, A-, B-, R-
- Error output nE+, nE-
Short-circuit protected
Yes
Programming interface
RS485 (≤600 m)
Interference immunity
EN 61000-6-2
Pulses per revolution
1 … 131072
Programmable parameters
- Pulse number
- Switch-off and switch-on speeds
- Switching delay time
Technical Data - Electrical Values (Speed Switch)
Switching accuracy
± 2 % (or 1 Digit)
Switching hysteresis
10 … 100 % adjustable
Switching outputs
1 output (Open collector)
Switching delay time
≤20 ms
Output switching capacity
30 VDC, ≤100 mA
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_Encoder_Size_10_ML_DoC_81376584.pdf
open_in_new Open