Baumer POG 86 + FSL
Dimension (flange) ø115 mm
Shaft Type ø11 mm solid shaft
Baumer Industrial absolute encoders

POG 86 + FSL Incremental encoder - combination

Baumer POG 86 + FSL features ø100…160 mm size, straight shaft, 3601 … 5000 pulses, optical sensing method and IP 56 protection EN 60529.

Series: HOG86 / POG86 — The incremental HeavyDuty standard →

Technical Specifications

Dimension (flange) ø115 mm
Shaft Type ø11 mm solid shaft
Product Description
  • Mechanical speed monitoring based on centrifugal force
  • Robust, compact housing
  • Two bearings with large distance, one at each end
  • High shaft load up to 350 N
  • TTL output driver for cable length up to 550 m
  • Terminal boxes, turn by 180°

Detailed Technical Data

Technical Data - Mechanical Design

Flange EURO flange B10
Resistance
  • IEC 60068-2-6
  • Vibration 5 g, 10-2000 Hz
  • IEC 60068-2-27
  • Shock 150 g, 1 ms
Material
  • Housing: aluminium, coated
  • Shaft: stainless steel
Speed (n) ≤1.25 · ns
Shaft type ø11 mm full mil
Connection 2x terminal box
Dimension (flange) ø115 mm
Protection EN 60529 IP 56
Corrosion protection
  • IEC 60068-2-52 Salt mist
  • for ambient conditions C4 according to ISO 12944-2
Approximate weight 1.9 kg
Operating temperature
  • -40...+100 °C
  • -25...+100 °C (>3072 pulses)
Operating torque (typical) 3 Ncm
Permissible shaft load
  • ≤250 N axial
  • ≤350 N radial
Rotor moment of inertia 220 gcm²
Switching speed range (ns) 850...4500 rpm (Δn = 2 rpm/s)

Technical Data - Electrical Values

Approval CE
Emitted interference EN 61000-6-3
Interference immunity EN 61000-6-2

Technical Data - Electrical Values (Encoder)

Phase shift 90 ° ±20°
Supply voltage
  • 9...30 VDC
  • 5 VDC ±5 %
Reference signal Zero pulse, width 90°
Consumption w/o load ≤100 mA
Duty cycle
  • 45…55 %
  • 40…60 % (>3072 pulses)
Detection method Optical
Output stages
  • HTL-P (heavy-duty line driver)
  • TTL/RS422
Output frequency
  • ≤120 kHz
  • ≤300 kHz (on request)
Output signals
  • K1, K2, K0 + inverted
  • Error output (option EMS)
Pulses per revolution 500 … 5000

Technical Data - Electrical Values (Centrifugal Switch)

Switching deviation ≤3 % (cw-ccw rotation)
Switching accuracy
  • ± 4 % (Δn = 2 rpm/s),
  • 20 % (Δn = 1500 rpm/s)
Switching hysteresis 40 % of switching speed
Switching outputs 1 output, speed control
Minimum switching current 50 mA
Output switching capacity
  • ≤6 A / 230 VAC
  • ≤1 A / 125 VDC
  • (EAC: <50 VAC / 75 VDC)

Documents

description Data sheet PDF · Baumer_POG-86-FSL_EN_20251117_DS.pdf open_in_new Open
description Data sheet PDF · Baumer_POG-86-+-FSL_EN_20251117_DS.pdf open_in_new Open
build Mounting instructions PDF · Baumer_POG86-FSL_DE_EN_202210_MI_11155818.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_EncoderFSL_ML_DoC_81376674.pdf open_in_new Open
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3