Article No
11706119
Measurement Range
0 … 2.5 bar
Initial Accuracy
≤ 0.5 - 0.7 % FS
Baumer
Pressure sensors
PP20H-2.3B18R.D115.412220.000 Pressure sensor
Baumer PP20H-2.3B18R.D115.412220.000 features low (up to 10 bar) pressure range, relative (gauge) pressure type and G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51) process connection.
Series: Hydrostatic level sensor with hygienic connection and IO-Link →
Technical Specifications
Article No
11706119
Measurement Range
0 … 2.5 bar
Initial Accuracy
≤ 0.5 - 0.7 % FS
Process Connection
G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)
Product Description
- All market typical hygienic connections available
- Resistant to all common CIP cleaning media
- Condensate-proof measuring cell
- Optionally available with IO-Link (in parallel to 4 ... 20 mA)
- Space-savng installations from DN 25 on
- Absolute pressure, relative pressure and vacuum measurement
Detailed Technical Data
IO-LINK INTERFACE
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
Dual Channel
- IO-Link / Analogue
- Analogue / SIO Mode
Device profile
Smart Sensor Profile
IO-Link port type
Class A
IO-Link version
1.1
Process data (cyclic)
- Pressure or temperature
- Switch state
- State of alert
- Scaling factor
Diagnostic data (acyclic)
- Ambient pressure
- Device temperature
- CPU temperature
- Operation time (since power-on)
- Device Status
- Power supply
Adjustable data (acyclic)
- Offset settings
- Switch parameters
- Measuring mode
Process connection
Wetted parts material
AISI 316L (1.4404)
Connection variants
G 1/2 A DIN 3852-E
Wet part material, membrane
AISI 316L (1.4435)
Performance characteristics
Pressure type
Relative (gauged)
Measuring range
0 … 2.5 bar
Max. measurement error
- ± 0.5 % FSR
- Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
Temperature coefficient
- ≤ 0.2 % FSR/10 K , measuring span
- ≤ 0.2 % FSR/10 K , zero point
Long-term stability
≤ 0.2 % FSR/a
Rise time (%10 … %90)
≤ 5 ms
Standard error of measurement (BFSL)
- ± 0.2 % FSR
- Including non-linearity, hysteresis and non-repeatability according BFSL
Compensated temperature range
-20 … 105 °C
Documents
build
Mounting instructions
PDF · Baumer_MAL_PP20H_D1_IO-Link_81331057_DE_EN_FR.pdf
open_in_new Open
verified_user
Declaration of Conformity – CE
PDF · Baumer_PP20x_ML_DoC_81355207.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – cULus
PDF · Baumer_Pressure-Sensors_Force-Strain_UL-E217824_EN_CoC_81158333 (1).pdf
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_PBMH_PP20H_EN_CoC_81158269.pdf
open_in_new Open
restaurant
Food Regulatory Declaration of Harmlessness
PDF · Baumer_PP20H_DE-EN-FR_FRDoH_81326820.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11706119
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Analog_Sensor_Interfaces_Guideline_V1.00_EN.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Switching_Output_Guideline_V1.00_EN.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Definitions of Sensor Properties_V1.1_EN.pdf
open_in_new Open