Article No
11275107
Measurement Range
0 … 0.4 bar
Initial Accuracy
≥ 1 % FS
Baumer
Pressure sensors
PP20S-2.1B11R.D115.052010.000 Pressure sensor
Baumer PP20S-2.1B11R.D115.052010.000 features very low (up to 2 bar) pressure range, relative (gauge) pressure type and 1/2-14 NPT process connection.
Series: PP20S — Precise pressure sensor for process applications →
Technical Specifications
Article No
11275107
Measurement Range
0 … 0.4 bar
Initial Accuracy
≥ 1 % FS
Process Connection
1/2-14 NPT
Detailed Technical Data
IO-LINK INTERFACE
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
IO-Link port type
Class A
IO-Link version
1.1
Process data (cyclic)
- Pressure or temperature
- Switch state
- State of alert
- Scaling factor
Diagnostic data (acyclic)
- Ambient pressure
- CPU temperature
- Unit temperature
- Operation time (since power-on)
Adjustable data (acyclic)
- Offset settings
- Switch parameters
- Measuring mode
Process connection
Connection variants
1/4-18 NPT
Wetted parts material
AISI 316L (1.4404)
Wetted parts material, membrane
AISI 316L (1.4435)
PERFORMANCE CHARACTERISTICS
Pressure type
Relative (gauge)
Measuring range
0 … 0.4 bar
Max. measurement error
- ± 1.0 % FSR
- Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
Temperature coefficient
- ≤ 0.2 % FSR/10 K , measuring span
- ≤ 0.2 % FSR/10 K , zero point
Long-term stability
≤ 0.2 % FSR/a
Rise time (%10 … %90)
≤ 5 ms
Standard error of measurement (BFSL)
- ± 0.5 % FSR
- Including non-linearity, hysteresis and non-repeatability according BFSL
Compensated temperature range
-20 … 125 °C
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_PP20x_ML_DoC_81355207.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11275107
open_in_new Open