Baumer Y91-3.4.3.B74.R
Article No 11194177
Measurement Range -1 … 1.5 bar
Initial Accuracy 0.5 - 0.7 % FS
Baumer Pressure sensors

Y91-3.4.3.B74.R Pressure sensor

Baumer Y91-3.4.3.B74.R features low (up to 10 bar) pressure range, relative (gauge) pressure type and 1/8-27 NPT process connection.

Series: Y91 — Pressure transmitter for process applications →

Technical Specifications

Article No 11194177
Measurement Range -1 … 1.5 bar
Initial Accuracy 0.5 - 0.7 % FS
Process Connection 1/8-27 NPT

Detailed Technical Data

Process connection

Connection variants 1/8-27 NPT
Wetted parts material, membrane Ceramic, 96% AL2O3

PERFORMANCE CHARACTERISTICS

Pressure type Relative (gauge)
Measuring range -1 … 1.5 bar
Temperature coefficient
  • ≤ 0.25 % FSR/10 K , zero point P > 1 bar
  • ≤ 0.15 % FSR/10 K , measuring range > 1 bar
Long-term stability 0.2 % FSR/a
Rise time (%10 … %90) ≤ 3 ms
Standard error of measurement (BFSL)
  • ≤ 0.3 % FSR
  • Including non-linearity, hysteresis and non-repeatability according BFSL
  • ≤ 1 % FSR , for P ≤ 1 bar and P= 600 bar
  • ≤ 1 % FSR , zero point error
  • ≤ 1 % FSR , span error P > 1 Bar
Compensated temperature range -10 … 55 °C

Documents

description Data sheet PDF · Baumer_Y91-Configurator_EN_20251027_DS.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_Y9_ML_DoC_81381987-1-.pdf open_in_new Open
view_in_ar CAD data COM · baumer-embedded.partcommunity.com open_in_new Open
electrical_services EPLAN macro (EPLAN Data Portal) WEB · dataportal.eplan.com/part-details/bau.11194177 open_in_new Open