Orbitmerret
Paperless Recorder
Paperless Recorder - Cards
OMR card - IN.08 Paperless Recorder - Cards
Orbit Merret OMR card - IN.08 features load cell / Strain gauge input signal and plug-in card (OMR 700 slot) mounting.
Technical Specifications
Input Signal
Load cell / Strain gauge
Mounting
Plug-in card (OMR 700 slot)
Detailed Technical Data
tune
Input
* – Number of inputs
2 input, isolated
LC – Range
- • selectable from menu
- • 1…4 mV/V
- • 2…8 mV/V
- • 4…16 mV/V
LC – Sensor supply
10 VDC, load > 80 Ohm
LC – Connection
6-wire
tune
Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,05 % of range + 1 digit
Speed
5…100 measurement/s
Overload capacity
- • 2x
- • 10x (t < 30 ms)
Digital filters
- • floating average | 2…30 measurements
- • exponential average | 2…100 measurement
Functions
Tare | resets the display on a non-zero input signal
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Power supply
Power supply
5 VDC, 24 VDC
Current consumption
< 1,5 W
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Protection class
IP00
Electrical safety
EN 61010-1, A2
Dielectric strength
- • 2,5 kVAC for 1 min. between bus and inputs
- • 1 kVAC for 1 min. on inputs
Insulation resistance
- • input, bus | 300 V (ZI), 150 V (Di)*
- • input, input | 150 V (ZI), 100 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, par.6
tune
Mechanical Characteristics
Dimensions
65 x 98 mm
Installation
plug-in card