Orbitmerret
Signal converters
Digital transducers
OMX 211PM Digital transducers
Orbit Merret OMX 211PM features DIN rail mounting and analog output (mA/V).
Technical Specifications
Input Signal
Process (4-20mA)
Mounting
DIN rail
Output / Communication
Analog output (mA/V)
Detailed Technical Data
tune
Input
* – Number of inputs
1 input
PM – Range
- • ±2 V
- • 1 MOhm
- • input 1
- • ±5 V
- • 1 MOhm
- • input 1
- • ±10 V
- • 1 MOhm
- • input 1
- • 0…5 mA
- • < 200 mV
- • input I
- • 0…20 mA
- • < 200 mV
- • input I
- • 4…20 mA
- • < 200 mV
- • input I
tune
Display
Signal LED
PWR, SET | Device status signaling (RGB)
tune
Settings
Control
The device is controlled and set by a single button on the front panel
OM Link
- • the company's communication interface for running, configuring and updating the device firmware (microUSB)
- • The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
15 ppm/°C
Accuracy
±0,1 % of range (for 20 measurements/s)
Speed
1…100 measurement/s
Overload capacity
- • 2x
- • 10x (t < 30 ms)
Linearisation
linear interpolation in 100 points (only via OM Link)
Digital filters
- • arithmetic average | 2…100 measurements
- • floating average | 2…30 measurement
- • exponential average | 2…100 measurement
- • rounding | setting of a fixed step for value changes
Functions
- • Tare | resets the display on a non-zero input signal
- • Teach-in | semiautomatic regime of input calibration
- • Simulation | simulation of the input signal/device function
Mat. functions
polynomial, inverse polynomial, logarithm, exponential, power, root
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Analog Outputs
Output sayısı
1 output
Type
İzoleli, programlanabilir with resolution of max.10,000 steps, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Non-linearity
±0,1 % of range
Ranges
0…10 V / 10...0 V (resistive load > 2.6 kOhm), 0...20 mA, 4…20 mA / 20...4 mA (aktivní/pasivní)
Compensation
600 Ohm/12 V
Error status
error message indicator (<3.0 mA)
tune
Sensor supply
Fixed
24 VDC/35 mA, isolate (only for 4...20mA)
tune
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current consumption
< 2,4 W/2,6 VA
Power supply protection
protected by a fuse inside the device
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 2,5 mm²
Stabilisation time
within 5 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
- • 2,5 kVAC for 1 min. between power supply and input
- • 2,5 kVAC for 1 min. between input and output
Insulation resistance
- • device power supply | 300 V (ZI), 255 V (DI)
- • input, output | 300 V (ZI)*
EMC
EN61326-1: 2006
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, par 6,9
Mechanical dayanıklılık
[Mechanical Characteristics]
Material
PA 66, flame-retardant UL 94 V-0 (black)
Dimensions
114,5 x 99 x 12,5 mm (w x h x d)
Installation
DIN rail, width 35 mm