OMX 333UQC Digital transducers
Orbit Merret OMX 333UQC features frequency / Counter input signal, DIN rail mounting and analog output (mA/V).
Technical Specifications
Input Signal
Frequency / Counter
Mounting
DIN rail
Output / Communication
Analog output (mA/V)
Detailed Technical Data
tune
Input
UQC – Input
- • selectable from menu
- • 0...30/300 V, comparison levels are adjustable from menu or automatic
UQC – Input frequency
- • 0,1 Hz…50 kHz (mode SINGLE)
- • 0,1 Hz…20 kHz (mode UP/DW)
- • 0,1 Hz…20 kHz (UP-DW)
- • 0,1 Hz…20 kHz (mode QUADR. - frequency)
- • 0,1 Hz…10 kHz (mode QUADR. - counter)
- • (for 50% duty cycle)
UQC – Measurement mode
- • SINGLE | Counter/frequency
- • QUADR | Counter/frekans for IRC sensor
- • UP/DW | Counter/frequency
- • UP - DW | Counter/frequency
- • TIME | Stopwatch
- • RTC | Clock
UQC – Time base
0,5/1/2/5/10 s
UQC – Calibration coefficient
0,00001…999999
UQC – Front setting
0…999999
UQC – Input filtresi
- • out
- • 5/40/100/1 000 Hz
UQC – Functions
- • Preset | initial non-zero value, which is always loaded after resetting the instrument
- • current value | single setting of the initial value
- • Summation | registration of counts during shift operation
External inputs – Number
1 input, contact input
External inputs – Functions
- • OFF | No function
- • HOLD | stops the measurement (option: Display - Analog output - Limits)
- • LOCK | Front panel tuşlarını kilitle
- • TARA | tare activation
- • CL.SUM. | Sum reset
- • CLR. ST. | input clears (presets) stop-watch/counter, Stop-watch also stops
tune
Display
Signal LED
- • L1, L2 | Limits L1, L2 (red)
- • Lo, Hi | Signalization, settings and errors (red/green)
tune
Settings
Control
The instrument is controlled and set by two buttons and a DIP açılış the front panel
OM Link
- • the company's communication interface for running, configuring and updating the device firmware
- • The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,1 % of range
Speed
0,5…80 measurement/s
Overload capacity
- • 2x
- • 10x (t < 30 ms)
Linearisation
25 noktalı lineer interpolasyon (only OM Link via)
Digital filters
- • exponential average | 2…100 measurements
- • rounding | sets the display step
- • input filter | transmits input signal range 5…1 000 Hz
- • 1/Fr. | filter for frequency conversion to time
Functions
- • Tare | resets the display on a non-zero input signal
- • Preset | initial non-zero value, which is loaded after each counter reset
- • Summation | registration of counts during shift operation
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Comparators
Type
Digital, adjustable from menu, contact bağlantısı < 50 ms
Mode
- • Hysteresis | sets the switching point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) switching delay
- • C-Pulse | automatic counter reset at the preset value
- • Once | switches ON at the limit, but opens only after a counter reset
- • On Run | output is active while stopwatch is running
Output
- • 1x relay, change contact (250 VAC/30 VDC, 3 A)
- • 2x relay, change contact (250 VAC/30 VDC, 3 A)
- • 1x open collector (30 VDC/100 mA)
- • 2x open collector (30 VDC/100 mA)
tune
Data Outputs
Protocol
ASCII
Data formatı
8 bit + parite none + 1 stop bit (ASCII)
Speed
600…230 400 Baud
RS 485
isolated, max. adresleme: 31 device
tune
Analog Outputs
Type
İzoleli, programlanabilir, 16-bit D / A converter, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Non-linearity
±0,1 % of range
Speed
value değişimine yanıt < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V
Error status
- • of rangeda 4...20mA
- • error message indicator (<3.0 mA)
- • current döngüsü kesintisi tespiti
tune
Power supply
Power supply
- • 10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms
- • 10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current consumption
< 2 W/2 VA
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation time
within 15 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
- • 2,5 kVAC for 1 min. between power supply, input and output
- • 2,5 kVAC 1 min. for input with data/analog output between
Insulation resistance
power supply | 550 V (ZI), 255 V (Di)*
EMC
EN 61326-1
tune
Mechanical Characteristics
Material
PA 66, flame-retardant UL 94 V-I (blue)
Dimensions
25 x 79 x 110 mm (w x h x d)
Installation
DIN rail, width 35 mm