Orbit Merret OMX 333UQC
Orbitmerret Signal converters Digital transducers

OMX 333UQC Digital transducers

Orbit Merret OMX 333UQC features frequency / Counter input signal, DIN rail mounting and analog output (mA/V).

Technical Specifications

Input Signal Frequency / Counter
Mounting DIN rail
Output / Communication Analog output (mA/V)

Detailed Technical Data

tune Input
UQC – Input
  • • selectable from menu
  • • 0...30/300 V, comparison levels are adjustable from menu or automatic
UQC – Input frequency
  • • 0,1 Hz…50 kHz (mode SINGLE)
  • • 0,1 Hz…20 kHz (mode UP/DW)
  • • 0,1 Hz…20 kHz (UP-DW)
  • • 0,1 Hz…20 kHz (mode QUADR. - frequency)
  • • 0,1 Hz…10 kHz (mode QUADR. - counter)
  • • (for 50% duty cycle)
UQC – Measurement mode
  • • SINGLE | Counter/frequency
  • • QUADR | Counter/frekans for IRC sensor
  • • UP/DW | Counter/frequency
  • • UP - DW | Counter/frequency
  • • TIME | Stopwatch
  • • RTC | Clock
UQC – Time base
0,5/1/2/5/10 s
UQC – Calibration coefficient
0,00001…999999
UQC – Front setting
0…999999
UQC – Input filtresi
  • • out
  • • 5/40/100/1 000 Hz
UQC – Functions
  • • Preset | initial non-zero value, which is always loaded after resetting the instrument
  • • current value | single setting of the initial value
  • • Summation | registration of counts during shift operation
External inputs – Number
1 input, contact input
External inputs – Functions
  • • OFF | No function
  • • HOLD | stops the measurement (option: Display - Analog output - Limits)
  • • LOCK | Front panel tuşlarını kilitle
  • • TARA | tare activation
  • • CL.SUM. | Sum reset
  • • CLR. ST. | input clears (presets) stop-watch/counter, Stop-watch also stops
tune Display
Signal LED
  • • L1, L2 | Limits L1, L2 (red)
  • • Lo, Hi | Signalization, settings and errors (red/green)
tune Settings
Control
The instrument is controlled and set by two buttons and a DIP açılış the front panel
OM Link
  • • the company's communication interface for running, configuring and updating the device firmware
  • • The OM Link program is also designed for visualising and logging measured values from multiple devices
tune Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,1 % of range
Speed
0,5…80 measurement/s
Overload capacity
  • • 2x
  • • 10x (t < 30 ms)
Linearisation
25 noktalı lineer interpolasyon (only OM Link via)
Digital filters
  • • exponential average | 2…100 measurements
  • • rounding | sets the display step
  • • input filter | transmits input signal range 5…1 000 Hz
  • • 1/Fr. | filter for frequency conversion to time
Functions
  • • Tare | resets the display on a non-zero input signal
  • • Preset | initial non-zero value, which is loaded after each counter reset
  • • Summation | registration of counts during shift operation
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune Comparators
Type
Digital, adjustable from menu, contact bağlantısı < 50 ms
Mode
  • • Hysteresis | sets the switching point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) switching delay
  • • C-Pulse | automatic counter reset at the preset value
  • • Once | switches ON at the limit, but opens only after a counter reset
  • • On Run | output is active while stopwatch is running
Output
  • • 1x relay, change contact (250 VAC/30 VDC, 3 A)
  • • 2x relay, change contact (250 VAC/30 VDC, 3 A)
  • • 1x open collector (30 VDC/100 mA)
  • • 2x open collector (30 VDC/100 mA)
tune Data Outputs
Protocol
ASCII
Data formatı
8 bit + parite none + 1 stop bit (ASCII)
Speed
600…230 400 Baud
RS 485
isolated, max. adresleme: 31 device
tune Analog Outputs
Type
İzoleli, programlanabilir, 16-bit D / A converter, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Non-linearity
±0,1 % of range
Speed
value değişimine yanıt < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V
Error status
  • • of rangeda 4...20mA
  • • error message indicator (<3.0 mA)
  • • current döngüsü kesintisi tespiti
tune Power supply
Power supply
  • • 10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms
  • • 10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current consumption
< 2 W/2 VA
tune Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation time
within 15 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
  • • 2,5 kVAC for 1 min. between power supply, input and output
  • • 2,5 kVAC 1 min. for input with data/analog output between
Insulation resistance
power supply | 550 V (ZI), 255 V (Di)*
EMC
EN 61326-1
tune Mechanical Characteristics
Material
PA 66, flame-retardant UL 94 V-I (blue)
Dimensions
25 x 79 x 110 mm (w x h x d)
Installation
DIN rail, width 35 mm

Documents

description
Data Sheets Datasheet OMX333 (v2015.1)
download Download
description
Data Sheets Datasheet OMX333UQC (v2023.1)
download Download
description
User Manuals Operating Instructions OMX333UQC (v2019.2.0)
download Download
description
User Manuals Operating Instructions OMX333IQC (v2013.1.0)
download Download
description
Certificates Certificate EU_Declaration_OMX333 (v2022)
download Download
description
Certificates Certificate Declaration_17050_OMX333 (v2022)
download Download
description
Certificates Certificate Seismic_test_OMX333 (v2015)
download Download
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3