Orbitmerret
Signal converters
Digital transducers
OMX 390LVDT Digital transducers
Orbit Merret OMX 390LVDT features LVDT sensor input signal, DIN rail mounting and analog output (mA/V).
Technical Specifications
Input Signal
LVDT sensor
Mounting
DIN rail
Output / Communication
Analog output (mA/V)
Detailed Technical Data
tune
Input
LVDT – Range
1/3/5 VAC with a frequency of 2.5/5/10 kHz
LVDT – Cable bağlantısı
3, 4, 5 or 6-wire
tune
Settings
Control
The device is operated and set up using two buttons on the front panel and a DIP switch on the side of the housing
İsteğe bağlı functions
- • TARE | Dara function activation
- • NUL. TA. | resets the tare
- • Teach-in | setting the analog input range
OM Link
- • the company's communication interface for running, configuring and updating the device firmware (microUSB)
- • The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
15 ppm/°C
Accuracy
±0,1 % of range
Speed
1…100 measurement/s
Overload capacity
- • 2x
- • 10x (t < 30 ms)
Linearisation
linear interpolation in 100 points (only via OM Link)
Digital filters
- • arithmetic average | 2…100 measurements
- • floating average | 2…30 measurement
- • exponential average | 2…100 measurement
- • rounding | sets the display step
Functions
- • Tare | resets the display on a non-zero input signal
- • Offset | compensation of the difference between the measured and the actual/required value
- • Min/max. value | measurement sırasında ulaşılan min./max. value kaydeder
- • Teach-in | semiautomatic regime of input calibration
- • Simulation | simulation of the input signal/device function
- • Delayed start | time during which no measurement is performed after the device is connected to the power supply
Mat. functions
polynomial, inverse polynomial, 1/x, logarithm, exponential, power, root
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Data Outputs
Output sayısı
1 output
Type
- • RS 485, isolated
- • 10/100BaseT, Modbus TCP/IP (Slave)
Protocol
MODBUS - RTU, MODBUS - TCP/IP
Data formatı
- • Format | 8bit + parity + stop bit
- • Parity | none / even / odd
- • Stop bit | 1 / 1.5 / 2
Speed
- • 600…230 400 Baud
- • 100 Mbit/s
RS 485
isolated, max. adresleme: 31 device
Address
MODBUS | < 246 instruments
Line termination
by internal resistor 120 Ohm
tune
Analog Outputs
Output sayısı
1 output
Type
İzoleli, programlanabilir, 16-bit D / A converter, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Accuracy
- • ±0,02 % full scale
- • ±0,03 % full scale (0…5 V)
- • ±0,05 % full scale (0…2 V / 0…5 mA)
Speed
value değişimine yanıt < 160 µs
Ranges
- • 0…2 / 5 / 10 V, ±10 V, resistive load > 1 k?
- • 0…5 / 20 mA / 4…20 mA, comp. < 600 Ohm / V
Error status
error message indicator (<3.0 mA)
tune
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current consumption
< 3,5 W/3,9 VA
Power supply protection
protected by a fuse inside the device
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation time
within 5 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Operating humidity
< 95 % relative nem, yoğuşmayan
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
- • 2,5 kVAC for 1 min. between power supply and input
- • 2,5 kVAC for 1 min. between input and output
Insulation resistance
- • device power supply | 300 V (ZI), 255 V (DI)
- • input, output | 300 V (ZI)*
EMC
EN 61326-1
RoHS
IEC 63000 : 2018
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, par 6,9
Mechanical dayanıklılık
EN 60068-2-6 ed. 2:2008
tune
Mechanical Characteristics
Material
PA 66, flame-retardant UL 94 V-0 (black)
Dimensions
25 x 79 x 90 mm (w x h x d)
Installation
DIN rail, width 35 mm