Orbit Merret OMX 390T
Orbitmerret Signal converters Digital transducers

OMX 390T Digital transducers

Orbit Merret OMX 390T features load cell / Strain gauge input signal, DIN rail mounting and analog output (mA/V).

Technical Specifications

Input Signal Load cell / Strain gauge
Mounting DIN rail
Output / Communication Analog output (mA/V)

Detailed Technical Data

tune Input
T – Range
  • • selectable from menu
  • • 1…2 mV/V
  • • 2…4 mV/V
  • • 4…8 mV/V
  • • 8…16 mV/V
T – Sensor supply
  • • 10 VDC, load > 80 Ohm
  • • 5 VDC, load > 80 Ohm
T – Connection
6-wire
External inputs – Number
2 input, contact input
External inputs – Functions
  • • OFF | No function
  • • HOLD | stops the measurement (option: Display - Analog output - Limits)
  • • BLOK.K. | locks the front panel keys
  • • TARA | tare activation
  • • NUL. TA. | resets the tare
  • • TAR.-NL. | Tare activation (<1 s) + tare reset (>1 s)
  • • T-IN.OF. | Activation of Teach-In for offset
  • • SOUCET | Control of cumulative measurement
  • • VZOREK | Start of a single measurement
  • • HLD.MIN | HOLD - Minimum value*
  • • HLD.MAX | HOLD - Maximum value*
  • • HLD.M-M | HOLD - MAX-MIN value*
  • • HLD.PRM. | HOLD - Average value*
  • • * | Value is calculated from the period since the previous activation of the external input
tune Settings
Control
The device is operated and set up using two buttons on the front panel and a DIP switch on the side of the housing
İsteğe bağlı functions
  • • ZAKAZ | düğmenin function none
  • • TARE | Dara function activation
  • • Teach-in | setting the analog input range
OM Link
  • • the company's communication interface for running, configuring and updating the device firmware (microUSB)
  • • The OM Link program is also designed for visualising and logging measured values from multiple devices
tune Device Accuracy and Functions
Temperature coefficient
15 ppm/°C
Accuracy
±0,02 % of range
Speed
1 000…7 200 measurements/s
Overload capacity
  • • 2x
  • • 10x (t < 30 ms)
Linearisation
linear interpolation in 100 points (only via OM Link)
Digital filters
  • • arithmetic average | 2…100 measurements
  • • floating average | 2…30 measurement
  • • exponential average | 2…100 measurement
  • • rounding | setting of a fixed step for value changes
Functions
  • • Tare | resets the display on a non-zero input signal
  • • Offset | compensation of the difference between the measured and the actual/required value
  • • Teach-in | semiautomatic regime of input calibration
  • • Simulation | simulation of the input signal/device function
  • • Delayed start | time during which no measurement is performed after the device is connected to the power supply
Mat. functions
polynomial, inverse polynomial, logarithm, exponential, power, root
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune Data Outputs
Type
  • • RS 485, isolated
  • • 10/100BaseT, Modbus TCP/IP (Slave)
Protocol
MODBUS - RTU, MODBUS - TCP/IP
Data formatı
  • • Format | 8bit + parity + stop bit
  • • Parity | none / even / odd
  • • Stop bit | 1 / 1.5 / 2
Speed
  • • 600…230 400 Baud
  • • 100 Mbit/s
Address
MODBUS | < 246 instruments
Line termination
by internal resistor 120 Ohm
tune Analog Outputs
Type
İzoleli, programlanabilir, 16-bit D / A converter, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Non-linearity
±0,024 % of range
Accuracy
  • • ±0,02 % full scale
  • • ±0,03 % full scale (0…5 V)
  • • ±0,05 % full scale (0…2 V / 0…5 mA)
Speed
value değişimine yanıt < 160 µs
Ranges
  • • 0…2 / 5 / 10 V, ±10 V, resistive load > 1 k?
  • • 0…5 / 20 mA / 4…20 mA, comp. < 600 Ohm / V
Error status
  • • error message indication
  • • current döngüsü kesintisi tespiti
tune Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current consumption
  • • < 3,4 W/3,3 VA
  • • < 5,0 W / 4,9 VA (load with 80 Ohm)
Power supply protection
protected by a fuse inside the device
tune Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation time
within 5 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-30°…85°C
Operating humidity
< 95 % relative nem, yoğuşmayan
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
  • • 2,5 kVAC for 1 min. between power supply and input
  • • 2,5 kVAC for 1 min. between input and output
Insulation resistance
  • • device power supply | 300 V (ZI), 255 V (DI)
  • • input, output | 300 V (ZI)*
EMC
EN 61326-1
RoHS
IEC 63000 : 2018
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, par 6,9
Mechanical dayanıklılık
EN 60068-2-6 ed. 2:2008

Documents

description
Data Sheets Datasheet OMX390T (v2024.1)
download Download
description
User Manuals Operating Instructions OMX390T_AO (v2024.1.02)
download Download
description
User Manuals Operating Instructions OMX390T_RS (v2024.1.02)
download Download
description
User Manuals Operating Instructions OMX390T_ETH (v2024.1.02)
download Download
description
Uygulama Notları Uygulama Notu External inputs (v2024.1)
download Download
description
Uygulama Notları Uygulama Notu Registry Modbus (v2023.001.0)
download Download
description
Certificates Certificate EU_Declaration_OMX390 (v2024)
download Download
description
Certificates Certificate Declaration_17050_OMX390 (v2024)
download Download
description
Certificates Certificate Seismic_test_OMX390 (v2024)
download Download
description
CAD OMX390T (v2023)
download Download
description
CAD OMX390T_ETH (v2023)
download Download
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3