Schmersal AES 1102.4 42 VAC
Order No 101126152
Certificates cULus
Schmersal Safe Signal Processing Security Relay and Control Modules

AES 1102.4 42 VAC Security Relay and Control Modules

Schmersal AES 1102.4 42 VAC features +0 ... +55 °C ambient temperature, 110 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 42 VAC
  • • Dimensions: 22.5mm×75mm×110mm
  • • Weight: 160 g
  • • Certification: cULus
  • • Contacts: 4 NC, 2 NO
  • • PL c

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • BNS series magnetic safety sensor monitoring
  • • 1 safety contact, STOP 0

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Warning for max. 50.000 switching cycles/year and max. 80% contact load
Depth 110 mm
Category 1
General note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
Height 75 mm
PFH value 1.14 x 10⁻⁶ /h
Number of LEDs 1
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, guard system
Mission time 20 Year(s)
Gross weight 160 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgCdO
Pollution degree 2
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. cable cross-section 2.5 mm²
Terminal (Mechanical) Screw terminals
Climatic Resistance EN 60068-2-3 BG-GS-ET-14
Stop Category 0
Ambient Temperature +0 ... +55 °C
Performance level c
Conventional thermal current 4 A
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 3,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Reset When Power is Removed Yes
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Suitable SIL Applications 1
Connection Diagram Note Monitoring of multiple protective doors using BNS magnetic safety sensors, to safeguard one or more protective doors up to PL c and Category 1. The connection diagram is shown with the protective doors closed and de-energized.
Permitted cable type Single-core rigid / flexible
Number of safety contacts 1
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 1.5 A
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 1 A
Overvoltage category III
Electrical Power Consumption 2.4 W
Min. Switching Capacity 10 mA
Rated operating voltage 42 VAC
AC Control Voltage 50Hz min. 35.7 VAC
AC Control Voltage 60Hz min. 35.7 VAC
Voltage Utilization Cat. AC-15 250 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 2 A
AC Control Voltage 50Hz max. 46.2 VAC
AC Control Voltage 60Hz max. 46.2 VAC
Rated impulse withstand voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/transport temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
Displayed Operating States Authorised operation
Number of NO (Normally Open) Contacts 2
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 4
Pull-In Delay on Automatic Start 100 ms
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3