Order No
101128982
Certificates
cULus
Schmersal
Safe Signal Processing
Security Relay and Control Modules
AES 1112 24 VDC Security Relay and Control Modules
Schmersal AES 1112 24 VDC features +0 ... +55 °C ambient temperature, 110 mm depth and 22.5 mm width.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×75mm×110mm
- • Weight: 122 g
- • Certification: cULus
- • Contacts: 2 NC, 1 NO
- • PL c
Standards
- • EN ISO 13849-1
- • EN IEC 61508
Product Features
- • BNS series magnetic safety sensor monitoring
- • 1 safety contact, STOP 0
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
for max. 50.000 switching cycles/year and max. 80% contact load
Depth
110 mm
Category
1
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
Height
75 mm
PFH value
1.14 x 10⁻⁶ /h
Number of LEDs
1
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system
Mission time
20 Year(s)
Gross weight
122 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgCdO
Pollution degree
2
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
Terminal (Mechanical)
Screw terminals
Climatic Resistance
EN 60068-2-3 BG-GS-ET-14
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance level
c
Conventional thermal current
4 A
Operating voltage
24 VDC -15 % / +15 %
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Suitable SIL Applications
1
Connection Diagram Note
To safeguard up to 2 protective doors to PL c and Category 1. Monitoring of 2 protective doors with BNS series magnetic sensors. If only one sensor is connected to S1, the terminals of S2 must be bridged.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
3 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
2 A
Overvoltage category
III
Electrical Power Consumption
2.4 W
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Rated impulse withstand voltage (Uimp)
4 kV
Emergency Release Delay
20 ms
Storage/transport temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
27.6 VDC
Displayed Operating States
Authorised operation
Number of NO (Normally Open) Contacts
1
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms