Schmersal AES 1112 24 VDC
Order No 101128982
Certificates cULus
Schmersal Safe Signal Processing Security Relay and Control Modules

AES 1112 24 VDC Security Relay and Control Modules

Schmersal AES 1112 24 VDC features +0 ... +55 °C ambient temperature, 110 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×75mm×110mm
  • • Weight: 122 g
  • • Certification: cULus
  • • Contacts: 2 NC, 1 NO
  • • PL c

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • BNS series magnetic safety sensor monitoring
  • • 1 safety contact, STOP 0

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Warning for max. 50.000 switching cycles/year and max. 80% contact load
Depth 110 mm
Category 1
General note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
Height 75 mm
PFH value 1.14 x 10⁻⁶ /h
Number of LEDs 1
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, guard system
Mission time 20 Year(s)
Gross weight 122 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgCdO
Pollution degree 2
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. cable cross-section 2.5 mm²
Terminal (Mechanical) Screw terminals
Climatic Resistance EN 60068-2-3 BG-GS-ET-14
Stop Category 0
Ambient Temperature +0 ... +55 °C
Performance level c
Conventional thermal current 4 A
Operating voltage 24 VDC -15 % / +15 %
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Reset When Power is Removed Yes
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Suitable SIL Applications 1
Connection Diagram Note To safeguard up to 2 protective doors to PL c and Category 1. Monitoring of 2 protective doors with BNS series magnetic sensors. If only one sensor is connected to S1, the terminals of S2 must be bridged.
Permitted cable type Single-core rigid / flexible
Number of safety contacts 1
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 3 A
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 2 A
Overvoltage category III
Electrical Power Consumption 2.4 W
Min. Switching Capacity 10 mA
Rated operating voltage 24 VDC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 2 A
Rated impulse withstand voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/transport temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
DC Min. Rated Control Voltage 20.4 VDC
DC Max. Rated Control Voltage 27.6 VDC
Displayed Operating States Authorised operation
Number of NO (Normally Open) Contacts 1
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 100 ms