Order No
101170036
Certificates
cULus
Schmersal
Safe Signal Processing
Security Relay and Control Modules
AES 1135 Security Relay and Control Modules
Schmersal AES 1135 features +0 ... +55 °C ambient temperature and 121 mm depth.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×100mm×121mm
- • Weight: 155 g
- • Certification: cULus
- • Contacts: 2 NC, 1 NO
- • PL d
Standards
- • EN ISO 13849-1
- • EN IEC 61508
Product Features
- • BNS series magnetic safety sensor monitoring
- • 1 safety contact, STOP 0
- • 2 signal outputs
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
Category
3
Faults
Failure of the safety relay to pull in or drop out; door contacts failing to open or close; cross-wire or short-circuit monitoring of the switch connections; disconnection of the switch connections; fault in the input circuits or relay control circuits of the safety monitoring module; fault or malfunction of the safety relay
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
Height
100 mm
PFH value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system
Mission time
20 Year(s)
Gross weight
155 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
Ag-Ni 10, gold-plated 0,2 µm
Pollution degree
2
Min. cable cross-section
0.25 mm²
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
Terminal (Mechanical)
Screw terminals
Climatic Resistance
EN 60068-2-3 BG-GS-ET-14
Ripple Voltage
10 %
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance level
d
Conventional thermal current
6 A
Operating voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
20,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following faults are registered by the safety monitoring modules and indicated by the ISD.
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
2
Connection Diagram Note
The wiring diagram is shown with guard doors closed and in the de-energised condition. 1 guard door up to PL d and Category 3. ISD tables in the appendix. Adjustable enabling delay. Position of K3 and K4 is monitored.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
6 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
6 A
Overvoltage category
III
Electrical Power Consumption
5 W
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
Number of Signal Outputs
2
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Rated impulse withstand voltage (Uimp)
4 kV
Input Signal HIGH (Signal 1)
10 … 30 VDC
Emergency Release Delay
20 ms
Storage/transport temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
28.8 VDC
Number of NO (Normally Open) Contacts
1
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
2