AES 1165.3-2316-2 24 VAC
Order No 101147946
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

AES 1165.3-2316-2 24 VAC

AES 1165.3-2316-2 24 VAC — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: +0 ... +55 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101147946. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 165 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • BG-GS-ET-14
  • • BG-GS-ET-20
  • • EN IEC 62061
  • • EN ISO 13849-1
  • • EN IEC 60947-5-1
  • • EN IEC 60947-5-5
  • • EN IEC 60204-1
  • • EN IEC 60947-1

Product Features

  • • Monitoring of BNS range magnetic safety sensors
  • • 1 safety contact, STOP 0

Technical Specifications

Depth 121 mm
Faults Fault on the input circuits or the relay control circuits of the safety monitoring module | Interruption of the switch connections | Failure of door contacts to open or close | Failure of the safety relay to pull-in or drop-out | Cross-wire or short-circuit monitoring of the switch connections
Mounting Snaps onto standard DIN rail to EN 60715
Notice for max. 50,000 switching cycles/year and max. 80% contact load | Discontinued product
Category 3
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 22.5 mm
PFH value 1.00 x 10⁻⁷ /h
EMC rating EMC-Directive
Height 100 mm
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type AC
Shock resistance 30 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 165 g
Number of LEDs 1
Ripple voltage 10 %
Climatic stress BG-GS-ET-14 | IEC 60947-5-3
Frequency range 50 Hz | 60 Hz
Gross weight 165 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material Ag-Ni 10 and 0.2 µm gold-plated
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 24 VAC -15 % / +10 %
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section 2.5 mm²
Note (ISD -Faults) The following faults are registered by the safety monitoring modules and indicated by ISD.
Ambient Temperature +0 ... +55 °C
Performance level d
Conventional thermal current 6 A
Mechanical life (min.) 20,000,000
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | To secure 2 guard doors up to PL d and Category 3 | Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit. | If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by | The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range
Terminal designations IEC/EN 60947-1
Terminal connection Screw terminals
Cross-circuit detection Yes
Input resistance at GND 2,000 Ω
Number of inputs for NC 2
Number of inputs for NO 1
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı +0 °C
Note (Delivery capacity) Not available!
Number of safety contacts 1
Maks. Ortam Sıcaklığı +55 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Tightening torque of Clips 0.6 Nm
Utilisation category DC-12 24_0.1
Number of auxiliary contacts 2
Overvoltage category III
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 24 VAC | 24 VAC -15% / +10% | 24 VDC -10%/+20%, residual ripple max. 10%
Switching capacity, maximum 250 VAC | 2 A | 24 VDC | 8 A
Switching capacity, minimum 10 VDC | 10 mA
Electrical power consumption 5 W
Input signal, LOW Signal "0" 0 … 2 VDC
Number of signalling outputs 2
Input signal, HIGH Signal "1" 10 … 30 VDC
Note (application conditions) Safety sensor | Guard system
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Depolama / Taşıma Sıcaklığı -25 ... +70 °C | -25 ... +75 °C
Pull-in delay at RESET, typically 20 ms
Current, Utilisation category AC-15 6 A
Current, Utilisation category DC-12 0.1 A
Current, Utilisation category DC-13 6 A
Integral system diagnostics, status Yes
Voltage, Utilisation category AC-15 230 VAC
Voltage, Utilisation category DC-12 24 VDC
Voltage, Utilisation category DC-13 24 VDC
Rated control voltage at DC, maximum 28.8 VDC
IP Degree of protection of the enclosure IP40
Rated control voltage at AC 50 Hz, maximum 26.4 VAC
Rated control voltage at AC 60 Hz, maximum 26.4 VAC
Storage and transport temperature, maximum +70 °C
Storage and transport temperature, minimum -25 °C
Rated AC voltage for controls at DC minimum 20.4 VDC
Reset after disconnection of supply voltage Yes
IP Degree of protection of clips or terminals IP20
Rated AC voltage for controls, 50 Hz, minimum 20.4 VAC
Rated AC voltage for controls, 60 Hz, minimum 20.4 VAC
Drop-out delay in case of emergency, typically 20 ms
IP Degree of protection of the installation space IP54
Drop-out delay in case of power failure, typically 80 ms
Pull-in delay at automatic start, maximum, typically 100 ms
Safety Integrity Level (SIL), suitable for applications in 2
Number of undelayed semi-conductor outputs with signaling function 2