Order No
101131903
Certificates
cULus
Schmersal
Safe Signal Processing
Security Relay and Control Modules
AES 1185 24 VDC Security Relay and Control Modules
Schmersal AES 1185 24 VDC features cam elyaf takviyeli termoplastik housing material, +0 ... +55 °C ambient temperature, 110 mm depth and 22.5 mm width.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×75mm×110mm
- • Weight: 135 g
- • Certification: cULus
- • Contacts: 3 NC, 3 NO
- • PL d
Standards
- • EN ISO 13849-1
- • EN IEC 61508
Product Features
- • BNS series magnetic safety sensor monitoring
- • 1 safety contact, STOP 0
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
for max. 50.000 switching cycles/year and max. 80% contact load
Depth
110 mm
Category
3
Faults
Failure of the safety relay to pull in or drop out; door contacts failing to open or close; cross-wire or short-circuit monitoring of the switch connections; disconnection of the switch connections; fault in the input circuits or relay control circuits of the safety monitoring module; fault or malfunction of the safety relay
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
Height
75 mm
PFH value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system
Mission time
20 Year(s)
Gross weight
135 g
Housing Material
Glass-fibre reinforced thermoplastic
Contact material
Ag-Ni, Au
Pollution degree
2
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
Number of NO Inputs
3
Number of NC Inputs
3
Terminal (Mechanical)
Screw terminals
Climatic Resistance
BG-GS-ET-14 IEC 60947-5-3
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance level
d
Conventional thermal current
4 A
Operating voltage
24 VDC -10 % / +20 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
50,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following faults are registered by the safety monitoring modules and indicated by the ISD.
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
2
Connection Diagram Note
The hinge axis must be 5 mm above. Minimum actuating radius on hinged guards 35 mm. Actuator not available separately.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
6 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
6 A
Overvoltage category
III
Electrical Power Consumption
5 W
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Rated impulse withstand voltage (Uimp)
4 kV
Input Signal HIGH (Signal 1)
12 … 30 VDC
Emergency Release Delay
20 ms
Storage/transport temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
28.8 VDC
Number of NO (Normally Open) Contacts
3
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
3
Pull-In Delay on Automatic Start
100 ms