Order No
101180845
Article Code
101180845
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Güvenlik İzleme Modülleri
AES 2535 UE: 24...230V AC/DC
Product Description
- • Voltage: 24 ... 230 VAC | Dimensions: 45mm×100mm×121mm | Weight: 359 g | Certification: cULus | Contacts: 2 NC, 1 NO | PL d
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • BNS serisi manyetik güvenlik sensörü izleme_x000D_
- • 4 güvenlik kontağı, STOP 0_x000D_
- • 2 sinyal çıkışı
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
Category
3
Faults
Safety of the relay not pulling or not releasing; Door contact not opening or not closing; Switch connection cross cable or short devre monitoring; Switch connection kesilmesi; Safety monitoring of the module input or relay kontrol devrelerinde fault; Safety in the relay fault or fonksiyon error
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
45 mm
Height
100 mm
PFH Value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor Guard system
Mission Time
20 Year(s)
Gross Weight
359 g
Housing Material
Cam elyaf takviyeli termoplastik
Contact Material
Ag-Ni 10 and 0,2 µm gold coated
Pollution Degree
2
Min. Cable Cross-Section
0.25 mm²
Vibration Resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
Terminal (Mechanical)
Threaded terminal block
Climatic Resistance
BG-GS-ET-14 IEC 60947-5-3
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance Level
d
Thermal Test Current
0.25
Operating Voltage
24 ... 230 VAC 24 ... 230 VDC
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
20,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Voltage Range Type
AC DC
Suitable SIL Applications
2
Connection Diagram Note
Connection diagram, guard door closed and enerji cut off in the state is shown. PL d and Category 3'e up to guard door. K3 and K4 konumu feedback supply circuit with is monitored. Start butonu feedback supply devresine can be connected.
Permissible Cable Type
Single core solid / esnek
Number of Safety Contacts
4
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.125
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
0.08333333333212067
Number of Auxiliary Contacts
1
Overvoltage Category
III
Electrical Power Consumption
5 W
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 ... 230 VAC 24 ... 230 VDC
Number of Signal Outputs
2
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
AC Control Voltage 50Hz max.
253 VAC
AC Control Voltage 60Hz max.
253 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Input Signal HIGH (Signal 1)
10 … 30 VDC
Emergency Release Delay
20 ms
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
253 VDC
Number of NO (Normally Open) Contacts
1
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
2