Order No
101120016
Certificates
cULus
Schmersal
Safe Signal Processing
Security Relay and Control Modules
AES 7112.3 24 VAC Security Relay and Control Modules
Schmersal AES 7112.3 24 VAC features +0 ... +55 °C ambient temperature, 58 mm depth and 105 mm width.
Product Description
- • Voltage: 24 VAC
- • Dimensions: 105mm×96mm×58mm
- • Weight: 140 g
- • Certification: cULus
- • Contacts: 2 NC, 4 NO
- • PL d
Standards
- • EN ISO 13849-1
- • EN IEC 61508
Product Features
- • BNS series magnetic safety sensor monitoring
- • 1 safety contact, STOP 0
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
for max. 50.000 switching cycles/year and max. 80% contact load
Depth
58 mm
Category
3
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
105 mm
Height
96 mm
PFH value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system
Mission time
20 Year(s)
Gross weight
140 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgSn0
Pollution degree
2
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Max. cable cross-section
1.5 mm²
Terminal (Mechanical)
Screw terminals
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance level
d
Conventional thermal current
5A
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
3,000,000 Cycles
Note (Contact Resistance)
In new condition
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
2
Connection Diagram Note
Monitoring of 1 guard door with a BNS series magnetic safety sensor. Additional sensors can be connected to S2. For safeguarding a guard door up to PL c and Category 1.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
2 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
2 A
Overvoltage category
III
Electrical Power Consumption
1.5 W
Min. Switching Capacity
10 mA
Rated operating voltage
24 VAC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
250 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Rated impulse withstand voltage (Uimp)
4 kV
Emergency Release Delay
20 ms
Storage/transport temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
Displayed Operating States
Authorised operation
Number of NO (Normally Open) Contacts
4
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms