Order No
101153270
Certificates
TÜV
Schmersal
Safe Signal Processing
Security Relay and Control Modules
AES 9107 Security Relay and Control Modules
Schmersal AES 9107 features +0 ... +65 °C ambient temperature, cage clamps rigid or flexible terminal connection, 60 mm depth and 160 mm width.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 160mm×80mm×60mm
- • Weight: 460 g
- • Contacts: 1 NC, 1 NO
- • PL d
Standards
- • EN ISO 13849-1
- • EN IEC 61508
Technical Specifications
Depth
60 mm
Category
3
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
160 mm
Height
80 mm
PFH value
1.00 x 10⁻⁷ /h
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system
Mission time
20 Year(s)
Gross weight
460 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Pollution degree
2
Min. cable cross-section
0.25 mm²
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section
2.5 mm²
Ripple Voltage
10 %
Stop Category
0
Ambient Temperature
+0 ... +65 °C
Performance level
d
Conventional thermal current
2 A
Operating voltage
24 VDC -15 % / +15 %
IP Protection (Housing)
IP65
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
20,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Terminal connection
Cage clamps rigid or flexible
Suitable SIL Applications
2
Number of safety contacts
1
Current Utilization Cat. AC-15
2 A
Current Utilization Cat. DC-13
2 A
Overvoltage category
III
Electrical Power Consumption
2.4 W
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
Rated impulse withstand voltage (Uimp)
4 kV
Storage/transport temperature
-25 ... +70 °C
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
27.6 VDC
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
1