Schmersal AES1337
Order No 101172210
Certificates cULus CCC
Schmersal Safe Signal Processing Security Relay and Control Modules

AES1337 Security Relay and Control Modules

Schmersal AES1337 features -25 ... +45 °C ambient temperature and 121 mm depth.

Product Description

  • • Dimensions: 22.5mm×100mm×121mm
  • • Weight: 280 g
  • • Certification: cULus CCC
  • • Contacts: 1 NC, 1 NO
  • • PL e

Standards

  • • EN IEC 60947-5-1
  • • EN IEC 61508

Product Features

  • • BNS series magnetic safety sensor monitoring
  • • 3 safety contacts, STOP 0
  • • 1 signal output

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Warning Discontinued product
Depth 121 mm
Category 4
General note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
Height 100 mm
PFH value 2.00 x 10⁻⁸ /h
Number of LEDs 4
Shock resistance 10 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, guard system
Mission time 20 Year(s)
Gross weight 280 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Start Input Yes
Pollution degree 2
Min. cable cross-section 0.25 mm²
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. cable cross-section 2.5 mm²
Terminal (Mechanical) Screw terminals
Climatic Resistance EN 60068-2-78
Stop Category 0
Ambient Temperature -25 ... +45 °C
Performance level e
Reset Edge Detection Yes
Conventional thermal current 6 A
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Suitable SIL Applications 3
Connection Diagram Note The hinge axis must be 5 mm above. Minimum actuating radius on hinged guards 250 mm. Actuator not available separately.
Permitted cable type Single-core rigid / flexible
Number of safety contacts 3
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 6 A
Current Utilization Cat. DC-13 6 A
Number of auxiliary contacts 1
Overvoltage category III
Electrical Power Consumption 3.5 VA
Min. Switching Capacity 10 mA
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 2 A
Earth Connection Detection Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Emergency Release Delay 20 ms
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
Diagnostic Coverage (DC) Level ≥ 99 %
DC Min. Rated Control Voltage 20.4 VDC
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Position relay K2 Position relay K1 Internal operating voltage Ui
Number of NO (Normally Open) Contacts 1
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 1
Pull-In Delay on Automatic Start 100 ms
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3