Order No
101172211
Schmersal
Safe Signal Processing
Security Relay and Control Modules
AES2285 Security Relay and Control Modules
Schmersal AES2285 features -25 ... +45 °C ambient temperature and 121 mm depth.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 45mm×100mm×121mm
- • Weight: 430 g
- • PL d
Standards
- • EN IEC 60947-5-1
- • EN IEC 61508
Product Features
- • Multi-evaluation of up to 6 safety guards
- • BNS series magnetic safety sensor monitoring
- • 2 safety contacts, STOP 0
- • 6 Signalling outputs
- • Additional contacts by means of output expander
- • Individual signal outputs for each guard door
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
Category
3
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
45 mm
Height
100 mm
PFH value
2.00 x 10⁻⁸ /h
Number of LEDs
3
Shock resistance
10 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system
Mission time
20 Year(s)
Gross weight
430 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgCdO, self-cleaning, positive drive
Start Input
Yes
Pollution degree
2
Min. cable cross-section
0.25 mm²
Vibration resistance
10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse
Yes
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
Terminal (Mechanical)
Screw terminals
Climatic Resistance
EN 60068-2-78
Ripple Voltage
10 %
Stop Category
0
Ambient Temperature
-25 ... +45 °C
Performance level
d
Reset Edge Detection
Yes
Conventional thermal current
6 A
Operating voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
3
Connection Diagram Note
The position of contactors K3 and K4 is monitored by the feedback circuit. Automatic start is programmed by connecting terminals X1/X3. Monitoring of 6 guard doors up to PL d and Category 3. Start button (S) with edge detection.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
2
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
6 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
6 A
Number of auxiliary contacts
1
Overvoltage category
III
Electrical Power Consumption
6.6 VA
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
Number of Signal Outputs
6
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
Removable Terminals
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Min. Number of Overlapping Contacts
1
Rated impulse withstand voltage (Uimp)
4 kV
Max. Number of Overlapping Contacts
6
Emergency Release Delay
20 ms
Storage/transport temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
Diagnostic Coverage (DC) Level
≥ 99 %
DC Min. Rated Control Voltage
20.4 VDC
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Position relay K2 Position relay K1 Internal operating voltage Ui
Release Delay on Power Failure
80 ms
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
6