Schmersal ASIM-C-M12-8P-2M
Order No 103004693
Certificates cULus
Schmersal Safe Switching and Monitoring AS-i Safety System

ASIM-C-M12-8P-2M AS-i Safety System

Schmersal ASIM-C-M12-8P-2M features cam elyaf termoplastik housing material, IP67 protection class, -20 ... +60 °C ambient temperature and 22 mm depth.

Product Description

  • • IP Rating: IP67
  • • Voltage: 26.5 ... 31.6 VDC
  • • Dimensions: 27.7mm×40.5mm×22mm
  • • Weight: 145 g
  • • Certification: cULus
  • • PL e

Standards

  • • EN IEC 62061

Product Features

  • • LED output 50 mA from AS-Interface
  • • Compact Safety-Input module
  • • Integrated in the passive junction
  • • for 2 potential-free NC contacts
  • • Protection class IP67

Technical Specifications

Depth 22 mm
Category 4
Width 27.7 mm
Height 40.5 mm
AS-i Profile S-7.B.F.0
Shock resistance 30 g / 11 ms
AS-i Version V 3.0
Mission time 20 Year(s)
Cable Material Polyurethane PUR
Cable length 2 m
Gross weight 145 g
Housing Material Glass-fibre thermoplastic
Protection Class III
Min. Relative Humidity 30 %
Pollution degree 3
Max. Relative Humidity 95 %
Note (Relative Humidity) Non-condensing, non-icing
Vibration resistance 10 … 57 Hz, amplitude 0.75 mm
Max. Risk Time 5 ms
AS-i Output DO 0 LED Output
IP protection class IP67
Max. reaction time 1 ms
Ambient Temperature -20 ... +60 °C
Performance level e
AS-i Input Channel 1 Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input Channel 2 Data bits DI 2 / DI 3 = dynamic code transmission
Terminal connection Connector, M12, 8-pole, A-coded
Suitable SIL Applications 3
Safety Functions Yes
AS-i Parameter Bits P0 AS-i communication monitoring
AS-i Max. Current Consumption 90 mA
AS-i Output DO 1...DO 3 No function
AS-i Input Module Address 0
Overvoltage category III
Rated operating voltage 26.5 ... 31.6 VDC (Reverse polarity protection)
Note (AS-i Parameter Bits) Set the parameter outputs to "1111" (0xF)
AS-i Parameter Bits P1...P3 No function
Rated impulse withstand voltage (Uimp) 0.8 kV
Storage/transport temperature -25 ... +80 °C
Integrated System Diagnostics Status Yes
Rated insulation voltage (Uᵢ) 32 VDC
Note (AS-i Input Module Address) Preset to address 0; can be changed with an AS-Interface bus master or handheld programming device
Note (LED Switching Condition Indication) (1) green LED (AS-i LED): AS-i supply voltage/Slave address=0 (2) red LED: AS-i communication error/Slave address=0 (3) yellow LED: I1=Safety input 1 status (4) yellow LED: I2=Safety input 2 status (5) Yellow LED:...