Order No
101161809
Article Code
101161809
Certificates
cULus ASi-SaW
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Şalterleri
AZ 16 ST1-AS ASI-SAW
Product Description
- • IP Rating: IP67 | Voltage: 18 ... 31.6 VDC | Weight: 115 g | Certification: cULus ASi-SaW | PL d
Standards
- • EN IEC 61508
Product Features
- • connector plug M12, bottom, 4-pole_x000D_
- • Termoplastik gövde_x000D_
- • Uzun ömürlü_x000D_
- • 52 mm x 90 mm x 30 mm_x000D_
- • AS-Interface LED status display_x000D_
- • Actuator coded_x000D_
- • Safety switch with separate actuator_x000D_
- • Entegre AS-Interface_x000D_
- • AS interface M12 Plug-in connection
Technical Specifications
PIN 1
AS-i +
PIN 2
n.c.
PIN 3
AS-Interface -
PIN 4
n.c.
Category
3
PFH Value
1.01 x 10⁻⁷ /h
AS-i ID Code
0xB
AS-i IO Code
0x0
AS-i Profile
S-0.B.F.E
Pushing Force
Yes
AS-i ID Code 1
0xF
AS-i ID Code 2
0xE
AS-i Version
V 2.1
Mission Time
20 Year(s)
Please Note
Single channel mekanizmaya tehlikeli hasar for fault of excluding kabul edilebilir that it is and to manipulation counter sufficient protection garanti that is done cases...
Current Consumption
50 mA
Gross Weight
115 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Protection Class
II
Locking Force
5 N
Pollution Degree
3
Connector Position
Bottom
Note (PFH Value)
up to max. 100,000 switching cycles/year
Sensor Length
30 mm
Scope of Delivery
Actuator additionally order must be.
AS-i Specification
Safety Slave
IP Protection Class
IP67
Max. Response Time
100 ms
Ambient Temperature
-25 ... +60 °C
Performance Level
d
Sensor Width
52 mm
Mechanical Life (min.)
1,000,000 Cycles
Sensor Height
90 mm
AS-i Input Channel 1
Veri bitleri DI 0 / DI 1 = dinamik kod iletimi
AS-i Input Channel 2
Veri bitleri DI 2 / DI 3 = dinamik kod iletimi
Terminal Connection
M12 connector plug, 4 pole (A coded)
Suitable SIL Applications
2
AS-i Input Module Address
0
Overvoltage Category
III
Rated Operating Voltage
18 ... 31.6 VDC (Reverse polarity protection)
Note (AS-i Parameter Bits)
Set the parameter outputs to "1111" (0xF)
AS-i Parameter Bits P0...P3
No function
Impulse Withstand Voltage (Uimp)
0.8 kV
Storage/Transport Temperature
-25 ... +85 °C
Integrated System Diagnostics Status
Yes
Rated Insulation Voltage (Uᵢ)
32 VDC
Note (AS-i Input Module Address)
Adres 0'a front set; AS-interface bus master or el type programlama device with changeable
Note (LED Switching Condition Indication)
(1) LED green: Supply voltage (2) red LED: Communication error / Slave address = 0 (3) LED yellow : Enabling status