Order No
101121960
Article Code
101121960
Certificates
cULus CCC
Schmersal
Emniyetli Anahtarlama ve Denetleme
Ayrı Aktüatörlü Emniyet Şalterleri
AZ 17-11ZK
Product Description
- • IP Rating: IP67 | Weight: 85 g | Certification: cULus CCC | PL d
Standards
- • EN ISO 13849-1
Product Features
- • cable gland M16_x000D_
- • 30 mm x 60 mm x 30 mm_x000D_
- • Termoplastik gövde_x000D_
- • Çift yalıtımlı_x000D_
- • Uzun ömürlü_x000D_
- • Kompakt gövde_x000D_
- • Evrensel kodlama_x000D_
- • Düşük gerilim ve akımlarda yüksek kontak güvenilirliği_x000D_
- • Kirlenmeye karşı duyarsız_x000D_
- • 8 actuating planes
Technical Specifications
Note
Torx T10
Mounting
Vidalar
Category
3
General Note
Bu terminasyon (IDC) method, iletken end to the use of gerek kalmadan esnek iletkenlerin kolay connection provides
Cable Entry
M16 x 1.5
Application Note
Slide-mounted guard cover removable cover hinged guard cover
Mission Time
20 Year(s)
Please Note
Single channel mekanizmaya tehlikeli hasar for fault of excluding kabul edilebilir that it is and to manipulation counter sufficient protection garanti that is done cases...
Gross Weight
85 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Contact Material
Silver
Locking Force
5 N
Pollution Degree
3
Min. Cable Cross-Section
0.75 mm²
Sensor Length
30 mm
Scope of Delivery
Actuator additionally order must be. Slot cover for dust-proof covering of the opening not in use
Max. Cable Cross-Section
1 mm²
IP Protection Class
IP67
Ambient Temperature
-30 ... +80 °C
Performance Level
d
Sensor Width
30 mm
Thermal Test Current
0.4166666666678793
Operating Principle
Mekanik
Switching Element
1 NA contact, 1 NK contact
Switching Principle
Slow hareket, pozitif opening NK contact
Mechanical Life (min.)
1,000,000 Cycles
Sensor Height
60 mm
Number of Cable Glands
1
B10D NA Contact Value
1,000,000 Cycles
B10D NC Contact Value
2,000,000 Cycles
Positive Opening Distance
11 mm
Fixing Screw Type
2x M4
Terminal Connection
IDC terminasyon method
Max. Actuation Speed
2 m/s
Max. Installation Altitude
2,000 m
Permissible Cable Type
Esnek
Number of Safety Contacts
1
Number of Actuation Directions
2
Current Utilization Cat. AC-15
0.16666666666787933
Current Utilization Cat. DC-13
0.16666666666787933
Note (Switching Element)
dual kesimli
Number of Auxiliary Contacts
1
Overvoltage Category
III
Max. Switching Frequency
2,000 /h
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Storage/Transport Temperature
-30 ... +85 °C
Coding Level (EN ISO 14119)
Low
Min. Permissible Cable Cross-Section
4 mm
Max. Permissible Cable Cross-Section
8 mm
Min. Positive Opening Force/Contact
17 N
Rated Insulation Voltage (Uᵢ)
250 VAC
Housing Cover Screw Torque (Min.)
0.7 Nm
Required Rated Short-Circuit Current
1,000 A
Housing Cover Screw Torque (Max.)
1 Nm