EPLAN
Yes
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
without function
Coding
Individual coding, multiple teaching
Category
4
Latching
Yes
General note
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.
PFH value
5.20 x 10⁻¹⁰ /h
Shock resistance
30 g / 11 ms
Series-wiring
Yes
Mission time
20 Year(s)
Net Ağırlık
528 g
Bağlantı Tipi
Connector M12, 8-pole, A-coded
Gross weight
528 g
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
II
Safety functions
Yes
Pollution degree
3
Scope of delivery
Actuator must be ordered separately.
Sensor length
35 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm
Actuator monitored
Yes
Operating current
50 mA
IP protection class
IP66 | IP69K | IP67
Ambient Temperature
+0 °C ... +60 °C | +0 ... +60 °C
Performance level
e
Sensor width
85 mm
Working Principle
RFID
Mechanical life (min.)
1,000,000
Sensor height
100 mm
Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Reaction time, maximum
100 ms
Traceparts, product ID
69-25102012-087491
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
+0 °C
Note (Delivery capacity)
Not available!
Switch distance, typical
2 mm
Voltage drop Ud, maximum
4 V
Duration of risk, maximum
200 ms
Number of safety contacts
2
Maks. Ortam Sıcaklığı
+60 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
AZ/AZM300-B1
Current consumption at 24V
5 mA
Design of control elements
short-circuit proof, p-type
Utilization Category DC-13
24 VDC / 0.25 A | 24_0.05
Note (Mechanical lifetime)
Actuating speed ≤ 0.5 m/s | > 50,000 operations for door weights ≤ 5 kg
Time to readiness, maximum
5,000 ms
Overvoltage category
3 | III
Current consumption at 24 V
5 mA
Leakage current Ir, maximum
0.5 mA
Switching frequency, approx.
0.5 Hz
Rated impulse withstand voltage (Uimp)
0.8 kV
Electrical fuse rating, maximum
2 A
Depolama / Taşıma Sıcaklığı
-10 ... +90 °C
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Assured switching distance "ON" Sao
1 mm
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Voltage, Utilisation category DC-13
24 VDC
Assured switching distance "OFF" Sar
20 mm
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
High
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Scope of delivery of mounting material
2 x M6
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+90 °C
Storage and transport temperature, minimum
-10 °C
Safety Integrity Level (SIL), suitable for applications in
3