Schmersal AZM 161 Z ST1-AS RAP
Order No 101209108
Certificates cULus ASi-SaW
Schmersal Safe Switching and Monitoring AS-i Safety System

AZM 161 Z ST1-AS RAP AS-i Safety System

Schmersal AZM 161 Z ST1-AS RAP features IP67 protection class, -25 ... +60 °C ambient temperature and 30 mm sensor length.

Series: AZM 161 AS →

Product Description

  • • IP Rating: IP67
  • • Voltage: 24 VDC
  • • Weight: 450 g
  • • Certification: cULus ASi-SaW
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • Solenoid supply 24 VDC (Aux)
  • • Door locking is monitored
  • • Manual release
  • • Solenoid kilit
  • • Thermoplastic housing
  • • High holding force 2000
  • • 130 mm x 90 mm x 30 mm
  • • Lock protected against incorrect locking
  • • Double insulated
  • • Long service life
  • • Entegre AS-Interface

Technical Specifications

PIN 1 AS-i +
PIN 2 Aux - (P)
PIN 3 AS-Interface -
PIN 4 Aux + (P)
Mounting Screws
Category 3
General note Locks with the power-to-lock principle may only be used in special cases after a thorough assessment of the accident risk, since interruption of the power supply or actuation of the main switch...
PFH value 1.01 x 10⁻⁷ /h
AS-i ID Code 0xB
AS-i IO Code 0x7
AS-i Profile S-7.B.F.E
Shock resistance 30 g / 11 ms
Application Note Sliding guard, removable guard, hinged guard
AS-i ID Code 1 0xF
AS-i ID Code 2 0xE
AS-i Version V 2.1
Mission time 20 Year(s)
Please note For applications where fault exclusion for dangerous damage to the single-channel mechanism is acceptable and adequate protection against manipulation is ensured...
Current consumption 500 mA
Fuse Rating 4 A
Gross weight 450 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Protection Class II
Min. Relative Humidity 30 %
Locking force 30 N
Pollution degree 3
Connector Position Centre
Max. Relative Humidity 95 %
Note (Relative Humidity) Non-condensing, non-icing
Note (PFH Value) up to max. 100,000 switching cycles/year
Sensor length 30 mm
Scope of delivery Actuator must be ordered separately.
Vibration resistance 10 … 150 Hz, amplitude 0.35 mm
Manual Lock Release Yes
AS-i Specification Safety Slave
AS-i Output DO 0 Solenoid control
AS-i Output DO 1 No function
AS-i Output DO 2 No function
AS-i Output DO 3 No function
IP protection class IP67
Max. reaction time 100 ms
Ambient Temperature -25 ... +60 °C
Performance level e
Sensor width 130 mm
Operating voltage 24 VDC -15% / +10% (stabilised PELV power supply)
Working Principle Electromechanical
Mechanical life (min.) 1,000,000 Cycles
Sensor height 90 mm
AS-i Input Channel 1 Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input Channel 2 Data bits DI 2 / DI 3 = dynamic code transmission
Force to Lock Yes
Fixing screw type 3x M6
Terminal connection M12 connector plug, 4-pole (A-coded)
Max. actuating speed 2 m/s
Suitable SIL Applications 2
Max. installation altitude 2,000 m
Max. Holding Force Fmax 2,600 N
Note (Manual Lock Release) For maintenance, installation, etc. Manual release using M5 triangular key, available as accessory
Solenoid Lock Monitored Yes
AS-i Parameter Bits P0 Actuator detected
AS-i Parameter Bits P1 Solenoid interlock locked
AS-i Parameter Bits P2 Solenoid voltage within tolerance range
AS-i Parameter Bits P3 Error message - locking/unlocking of the solenoid interlock blocked
Note (Performance Level) Information about the safety classification of the guard locking function can be found in the "Operating instructions" or "Use and mounting" instructions...
AS-i Max. Current Consumption 100 mA
Number of actuating directions 3
AS-i Input Module Address 0
Overvoltage category III
Max. switching frequency 1,000 /h
Rated operating voltage 24 VDC
Note (AS-i Parameter Bits) Set the parameter outputs to "1111" (0xF). FID: peripheral error
Note (Auxiliary DC Voltage) stabilised PELV power supply
Rated impulse withstand voltage (Uimp) 0.8 kV
Storage/transport temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Coding level (EN ISO 14119) Low
Holding Force FZh (EN ISO 14119) 2,000 N
Rated insulation voltage (Uᵢ) 32 VDC
Note (AS-i Input Module Address) Preset to address 0; can be changed with an AS-Interface bus master or handheld programming device
Play in Direction of Actuation 5.5 mm
Note (LED Switching Condition Indication) (1) LED yellow: Channel 2 / AS-i SaW Bit 2.3 (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3