AZM 161 Z ST1-AS RIP ED/TU-B1
Order No 103045781
Certificates cULus, ASi-SaW cULus
Schmersal Safe Switching and Monitoring AS-i Emniyet Sistemi

AZM 161 Z ST1-AS RIP ED/TU-B1 AS-i Emniyet Sistemi

AZM 161 Z ST1-AS RIP ED/TU-B1 — Schmersal AS-i Emniyet Sistemi. Key specifications: Working Principle: electromechanical; IP protection class: IP67; Ambient Temperature: -25 ... +60 °C | -30 ... +60 °C; Sensor length: 30 mm; Sensor width: 130 mm. Article number: 103045781. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 497 g
  • • Sertifika: cULus, ASi-SaW cULus

Standards

  • • EN IEC 61508
  • • EN IEC 62026-2
  • • EN ISO 13849-1
  • • EN IEC 60947-5-1

Product Features

  • • Solenoid interlock
  • • Thermoplastic enclosure
  • • High holding force 2000 N
  • • Interlock with protection against incorrect locking.
  • • Double-insulated
  • • Long life
  • • Integrated AS-Interface

Technical Specifications

EPLAN Yes
PIN 1 AS-i +
PIN 2 Aux - (P)
PIN 3 AS-Interface -
PIN 4 Aux + (P)
Mounting Screws
Category 3 | 1
General note Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
PFH value 1.01 x 10⁻⁷ /h | 1.14 x 10⁻⁶ /h
Traceparts Yes
Fuse rating 4 A
AS-i Profile S-7.B.F.E
AS-i Version V 2.1
Please note: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
AS-i, ID-Code 0xB
AS-i, IO-Code 0x7
Shock resistance 30 g / 11 ms
AS-i, ID-Code1 0xF
AS-i, ID-Code2 0xE
Emergency exit Yes
Mission time 20 Year(s)
Latching force 30 N | 5 / 30 N
Manual release Yes
Net Ağırlık 497 g
Bağlantı Tipi Connector plug M12, 4-pole, (A-coding)
Power to unlock Yes
Gross weight 497 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Note (PFH-value) up to max. 100,000 switching cycles/year
Protection class II
Pollution degree 3
Operating voltage 24 VDC -15 % / +10 % (stabilised PELV power supply)
Relative humidity 30 ... 95 %
Scope of delivery Actuator must be ordered separately.
Sensor length 30 mm
Vibration resistance 10 … 150 Hz, amplitude 0.35 mm
AS-i Outputs, DO 0 Solenoid control
AS-i Outputs, DO 1 No Function
AS-i Outputs, DO 2 No Function
AS-i Outputs, DO 3 No Function
AS-i Specification Safety-Slave
Connector position Centre
Current consumption 500 mA
IP protection class IP67
Note voltage AUX DC stabilised PELV power supply
Ambient Temperature -25 ... +60 °C | -30 ... +60 °C
Performance level e | c | d
Sensor width 130 mm
Working Principle electromechanical
Mechanical life (min.) 1,000,000
Sensor height 90 mm
AS-i Input, Channel 1 Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2 Data bits DI 2 / DI 3 = dynamic code transmission
Note (Emergency exit) For cases of danger | Actuation from within the hazardous area
AS-i Device protection Internal short-circuit proof
Reaction time, maximum 100 ms
AS-i Parameter bits, P0 Actuator detected
AS-i Parameter bits, P1 Solenoid interlock locked
AS-i Parameter bits, P2 Magnet voltage in tolerance range
AS-i Parameter bits, P3 Error message - locking/unlocking of the solenoid interlock blocked
Max. actuating speed 2 m/s
Min. Ortam Sıcaklığı -25 °C
Note (Performance Level) Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.
Note (Relative humidity) non-condensing | non-icing
AS-i Input module address 0
Maks. Ortam Sıcaklığı +60 °C
Type of the fixing screws 3x M6
Relative humidity, maximum 95 %
Relative humidity, minimum 30 %
Overvoltage category 3 | III
Holding force Fmax, maximum 2,600 N
Max. switching frequency 1,000 /h
Nominal Çalışma Voltajı 26.5 ... 31.6 VDC (Protection against polarity reversal) | 24 VDC
Note (AS-i Parameter bits) Set the parameter outputs to "1111" (0xF) | FID: periphery error
Solenoid interlock monitored Yes
Note (AS-i Operating voltage) Protection against polarity reversal
Note (application conditions) removable guard | hinged safety guard | sliding safety guard
Rated impulse withstand voltage (Uimp) 0.8 kV
Number of actuating directions 3
AS-i Operating voltage, minimum 26.5 VDC
Note (AS-i Input module address) Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
AS-i Current consumption, maximum 100 mA
Depolama / Taşıma Sıcaklığı -40 ... +85 °C | -25 ... +85 °C
Rated insulation voltage (Uᵢ) 32 VDC
AS-i Operating voltage AS-i maximum 31.6 VDC
Integral system diagnostics, status Yes
Protection class (Operating resource) 2
Coding level according to EN ISO 14119 High
Note (LED switching conditions display) (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 | (1) LED yellow: Channel 2 / AS-i SaW Bit 2.3 | (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected
Actuating play in direction of actuation 5.5 mm
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -25 °C
Holding force FZh in accordance with EN ISO 14119 2,000 N
Permissible installation altitude above sea level, maximum 2,000 m
Safety Integrity Level (SIL), suitable for applications in 1 | 2

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3