EPLAN
Yes
PIN 1
AS-i +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)
Mounting
Screws
Category
3 | 1
General note
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
PFH value
1.01 x 10⁻⁷ /h | 1.14 x 10⁻⁶ /h
Traceparts
Yes
Fuse rating
4 A
AS-i Profile
S-7.B.F.E
AS-i Version
V 2.1
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
AS-i, ID-Code
0xB
AS-i, IO-Code
0x7
Shock resistance
30 g / 11 ms
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
Emergency exit
Yes
Mission time
20 Year(s)
Latching force
30 N | 5 / 30 N
Manual release
Yes
Net Ağırlık
497 g
Bağlantı Tipi
Connector plug M12, 4-pole, (A-coding)
Power to unlock
Yes
Gross weight
497 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Note (PFH-value)
up to max. 100,000 switching cycles/year
Protection class
II
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Relative humidity
30 ... 95 %
Scope of delivery
Actuator must be ordered separately.
Sensor length
30 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Specification
Safety-Slave
Connector position
Centre
Current consumption
500 mA
IP protection class
IP67
Note voltage AUX DC
stabilised PELV power supply
Ambient Temperature
-25 ... +60 °C | -30 ... +60 °C
Performance level
e | c | d
Sensor width
130 mm
Working Principle
electromechanical
Mechanical life (min.)
1,000,000
Sensor height
90 mm
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
Note (Emergency exit)
For cases of danger | Actuation from within the hazardous area
AS-i Device protection
Internal short-circuit proof
Reaction time, maximum
100 ms
AS-i Parameter bits, P0
Actuator detected
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
Magnet voltage in tolerance range
AS-i Parameter bits, P3
Error message - locking/unlocking of the solenoid interlock blocked
Max. actuating speed
2 m/s
Min. Ortam Sıcaklığı
-25 °C
Note (Performance Level)
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.
Note (Relative humidity)
non-condensing | non-icing
AS-i Input module address
0
Maks. Ortam Sıcaklığı
+60 °C
Type of the fixing screws
3x M6
Relative humidity, maximum
95 %
Relative humidity, minimum
30 %
Overvoltage category
3 | III
Holding force Fmax, maximum
2,600 N
Max. switching frequency
1,000 /h
Nominal Çalışma Voltajı
26.5 ... 31.6 VDC (Protection against polarity reversal) | 24 VDC
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
Solenoid interlock monitored
Yes
Note (AS-i Operating voltage)
Protection against polarity reversal
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Rated impulse withstand voltage (Uimp)
0.8 kV
Number of actuating directions
3
AS-i Operating voltage, minimum
26.5 VDC
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
AS-i Current consumption, maximum
100 mA
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C | -25 ... +85 °C
Rated insulation voltage (Uᵢ)
32 VDC
AS-i Operating voltage AS-i maximum
31.6 VDC
Integral system diagnostics, status
Yes
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
High
Note (LED switching conditions display)
(3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 | (1) LED yellow: Channel 2 / AS-i SaW Bit 2.3 | (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected
Actuating play in direction of actuation
5.5 mm
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Holding force FZh in accordance with EN ISO 14119
2,000 N
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
1 | 2