Note
All indications including the conductor ferrules. | Electrical life on request. | The tightening sequence of the cover screws must be observed. This can be found in the attached drawing in the “Pictures” tab. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Mounting
Screws
Category
3 | 1
Unlocking
Twist-to-unlock mechanism (auxiliary release)
Cable Cross-Section
0.25 mm² ... 1.5 mm²(All indications including the conductor ferrules.) | 0.25 mm² ... 0.75 mm² (All indications including the conductor ferrules.) | 0.25 mm² ... 1.5 mm² (All indications including the conductor ferrules.)
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Strip length
6 mm
Cable entry
4 x M16 x 1,5
Mission time
20 Year(s)
Latching force
30 N | 5 / 30 N
Manual release
Yes
Connection type
Screw terminals; Cage clamps; Connector plug M12, 4-pole, (A-coding); Connector plug M12, 8-pole, (A-coding); 2 x Connector plug M12, 4-pole, A-coding
Power to unlock
Yes
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material
Silver
Protection class
II
Min. cable cross-section
0.25 mm²
Scope of delivery
Actuator must be ordered separately.
Sensor length
45 mm
Max. cable cross-section
1.5 mm²
IP protection class
IP67
Ambient Temperature
-30 ... +60 °C
Performance level
e | c | d
Sensor width
130 mm
Conventional thermal current
6 A
Working Principle
electromechanical
Switching element
Magnet: 1 NO contact, 2 NC contacts / Actuator: 1 NO contact, 2 NC contacts
Switching principle
slow action, positive break NC contact
Degree of protection
IP67
Mechanical life (min.)
1,000,000
Sensor height
90 mm
Allowed type of cable
solid single-wire | solid multi-wire | flexible
Magnet switch-on time
100 %
Maks. Sigorta Değeri
6 A gG D-fuse
Note (Manual release)
On the cover side | For manual release using M5 triangular key, available as accessory
Positive break travel
10 mm
Rated control voltage
110 VAC | 230 VAC
Interlocking principle
Power to unlock
Terminal connection
cage terminals
Type of the screw head
Flat head screw
Max. actuating speed
2 m/s
Increased latching force
Yes
Min. Ortam Sıcaklığı
-30 °C
Note (Delivery capacity)
Not available!
Note (Performance Level)
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.
Note (Relative humidity)
non-condensing | non-icing
Number of safety contacts
3 / 4 / 5 | 4
Maks. Ortam Sıcaklığı
+60 °C
Type of the fixing screws
3x M5
Utilization Category AC-15
230 VAC / 4 A / Screw terminals | 230_4
Utilization Category DC-13
24 VDC / 4 A | 24_2.5
Number of auxiliary contacts
1 / 2 | 2
Holding force Fmax, maximum
2,600 N
Max. switching frequency
1,000 /h
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Positive break force, minimum
20 N
Rated impulse withstand voltage (Uimp)
4 kV
Number of actuating directions
3
B10D Normally-open contact (NO)
1,000,000
B10D Normally-closed contact (NC)
2,000,000
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C | -30 ... +85 °C
Rated insulation voltage (Uᵢ)
250 VAC | 250 VConnector, 4 poles - 250 VConnector, 8 poles - 60 V
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
2.5 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
10 W
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
Low
Actuating play in direction of actuation
5.5 mm
Colour of the upper part of the enclosure
Black
Colour of the bottom part of the enclosure
black
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Positive break force per NC contact, minimum
10 N
Holding force FZh in accordance with EN ISO 14119
2,000 N
Permissible installation altitude above sea level, maximum
2,000 m
Tightening torque of the fastening screws for the housing cover
0.6 Nm