PIN 1
AS-i +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)
Category
3 | 1
General note
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
PFH value
1.01 x 10⁻⁷ /h | 1.16 x 10⁻⁶ /h
Fuse rating
4 A
AS-i Profile
S-7.B.F.E
AS-i Version
V 2.1
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
AS-i, ID-Code
0xB
AS-i, IO-Code
0x7
Holding force
1,000 N
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
Mission time
20 Year(s)
Latching force
5 N | 5 / 30 N
Net Ağırlık
300 g
Bağlantı Tipi
Connector plug M12, 4-pole, (A-coding)
Power to unlock
Yes
Gross weight
300 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Note (PFH-value)
up to max. 100,000 switching cycles/year
Protection class
II
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Relative humidity
30 ... 95 %
Scope of delivery
Actuator must be ordered separately.
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Specification
Safety-Slave
Actuator monitored
Yes
Current consumption
500 mA
IP protection class
IP67
Note voltage AUX DC
stabilised PELV power supply
Ambient Temperature
-25 ... +55 °C
Performance level
c | d
Sensor width
90 mm
Working Principle
electromechanical
Mechanical life (min.)
1,000,000
Sensor height
75.5 mm
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Device protection
Internal short-circuit proof
Reaction time, maximum
100 ms
AS-i Parameter bits, P0
Safety guard and actuator detected
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
No function
AS-i Parameter bits, P3
No function
Max. actuating speed
2 m/s
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing | non-icing
AS-i Input module address
0
Maks. Ortam Sıcaklığı
+55 °C
Relative humidity, maximum
95 %
Relative humidity, minimum
30 %
Overvoltage category
3 | III
Nominal Çalışma Voltajı
24 VDC -15% / +10% (stabilised PELV) | 24 VDC | 26.5 ... 31.6 VDC (Protection against polarity reversal)
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
Note (AS-i Operating voltage)
Protection against polarity reversal
Rated impulse withstand voltage (Uimp)
0.8 kV
Number of actuating directions
2
AS-i Operating voltage, minimum
26.5 VDC
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
AS-i Current consumption, maximum
100 mA
Depolama / Taşıma Sıcaklığı
-25 ... +85 °C | -40 ... +85 °C
Rated insulation voltage (Uᵢ)
32 VDC
AS-i Operating voltage AS-i maximum
31.6 VDC
Integral system diagnostics, status
Yes
Protection class (Operating resource)
2
Note (LED switching conditions display)
(3) LED yellow : Enabling status | (1) LED green: Supply voltage | (2) red LED: Communication error / Slave address = 0
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Safety Integrity Level (SIL), suitable for applications in
1 | 2