Note
Electrical life on request. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Mounting
Screws
Category
3 | 1
General note
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Cable entry
2 x M20
Power to lock
Yes
Mission time
20 Year(s)
Latching force
20 N
Frequency range
50 Hz | 60 Hz
Housing Material
Glass-fibre, reinforced thermoplastic
Contact material
Silver
Protection class
II
Actuator rotation
0 °
Emergency release
Yes
Min. cable cross-section
0.5 mm², flexible | 0.5 mm², rigid
Scope of delivery
Actuator must be ordered separately.
Sensor length
41 mm
Max. cable cross-section
2.5 mm², flexible | 2.5 mm², rigid | 1.5 mm², flexible with conductor ferrule
Operating current
4,000 mA
IP protection class
IP65
Ambient Temperature
-25 ... +55 °C
Performance level
c | d
Sensor width
52 mm
Conventional thermal current
4 A
Working Principle
electromechanical
Switching element
Magnet: 1 NO contact, 1 NC contact / Actuator: 1 NO contact
Switching principle
slow action, positive break NC contact
Mechanical life (min.)
1,000,000
Sensor height
178 mm
Magnet switch-on time
100 %
Maks. Sigorta Değeri
4 A gG D-fuse to DIN EN 60269-1
Positive break travel
3.5 mm
Rated control voltage
230 VAC
Interlocking principle
Power to lock
Number of cable glands
2
Terminal connection
Screw terminals
Max. actuating speed
0.3 m/s
Material of the actuator
Zinc-plated metal
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Emergency release)
For cases of danger | Mounting only outside the guarded area
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
with double break
Number of safety contacts
1 / 2 / 3 / 4 | 1
Maks. Ortam Sıcaklığı
+55 °C
Type of the fixing screws
2x M5
Number of auxiliary contacts
1 / 2 | 2
Holding force Fmax, maximum
2,550 N
Max. switching frequency
1,200 /h
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Material of the latching bolt
Die-cast zinc
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Positive break force, minimum
20 N
Rated impulse withstand voltage (Uimp)
4 kV
Number of actuating directions
4
B10D Normally-open contact (NO)
1,000,000
B10D Normally-closed contact (NC)
2,000,000
Rated insulation voltage (Uᵢ)
250 V
Current, Utilisation category AC-1
4 A
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
4 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
8.5 W
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
Low
Holding force FZh in accordance with EN ISO 14119
1,950 N