AZM 200CC-T-SD2P
Order No 101193280
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

AZM 200CC-T-SD2P

AZM 200CC-T-SD2P — Schmersal product. Key specifications: Working Principle: inductive; Housing Material: Glass-fibre, reinforced thermoplastic; IP protection class: IP67; Ambient Temperature: -25 ... +60 °C | -30 ... +60 °C; Sensor length: 50 mm. Article number: 101193280. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Sertifika: cULus

Standards

  • • EN IEC 61508
  • • EN IEC 60947-5-1
  • • EN IEC 60947-5-3
  • • EN ISO 13849-1

Product Features

  • • Guard locking monitored
  • • serial diagnostic output
  • • Thermoplastic enclosure
  • • Electronic contact-free, coded system
  • • Max. length of the sensor chain 200 m
  • • Self-monitoring series-wiring
  • • 3 LEDs to show operating conditions
  • • Sensor technology permits an offset between actuator and interlock of ± 5 mm  vertically and ± 1,5 mm horizontally
  • • Intelligent diagnosis

Technical Specifications

Note Torx T10 | All indications including the conductor ferrules.
EPLAN Yes
Category 4
General note As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Cable Cross-Section 0.25 mm² ... 1.5 mm²(All indications including the conductor ferrules.) | 0.25 mm² ... 0.75 mm² (All indications including the conductor ferrules.)
Voltage type DC
Shock resistance 30 g / 11 ms
Series-wiring Yes
Mission time 20 Year(s)
Latching force 30 N
Manual release Yes
Bağlantı Tipi Spring pulley connection
Power to unlock Yes
Housing Material Glass-fibre, reinforced thermoplastic
Protection class II
Safety functions Yes
Pollution degree 3
Min. cable cross-section 0.25 mm²
Operating voltage 24 VDC -15 % / +10 %
Operation current 150 mA
Relative humidity 30 ... 95 %
Scope of delivery Triangular key for AZM 200 | Actuator must be ordered separately.
Sensor length 50 mm
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Max. cable cross-section 1.5 mm²
Serial diagnostics Yes
Wire cross-section 23 ... 15 AWG
Wiring capacitance 50 nF
Operating current 1,200 mA
IP protection class IP67
Ambient Temperature -25 ... +60 °C | -30 ... +60 °C
Performance level e
Sensor width 40 mm
Working Principle inductive
Mechanical life (min.) 1,000,000
Note (series-wiring) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height 220 mm
Switching thresholds -3 V … 5 V (Low) | −3 V … 5 V (Low) | 15 V … 30 V (High)
Allowed type of cable solid single-wire | solid multi-wire | flexible
Magnet switch-on time 100 %
Electrical fuse rating short-circuit proof, p-type
Reaction time, maximum 60 ms
Cross-circuit detection Yes
Max. actuating speed 0.2 m/s
Short circuit detection Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Note (Relative humidity) non-condensing
Note (holding force FZh) 1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Voltage drop Ud, maximum 4 V
Duration of risk, maximum 120 ms
Number of safety contacts 2
Maks. Ortam Sıcaklığı +60 °C
Note (holding force Fmax) 1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Recommendation (actuator) AZ/AZM 200-B1
Design of control elements short-circuit proof, p-type
Utilization Category DC-13 24 VDC / 0.25 A
Operating voltage, maximum 26.4 VDC
Operating voltage, minimum 20.4 VDC
Relative humidity, maximum 95 %
Relative humidity, minimum 30 %
Time to readiness, maximum 4,000 ms
Overvoltage category 3 | III
Current consumption at 24 V 5 mA
Holding force Fmax, maximum 2,600 N
Leakage current Ir, maximum 0.5 mA
Nominal Çalışma Voltajı 24 VDC
Wire cross-section, maximum 15 AWG
Wire cross-section, minimum 23 AWG
Solenoid interlock monitored Yes
Switching frequency, approx. 1 Hz
Rated impulse withstand voltage (Uimp) 0.8 kV
Fuse rating to UL 508, maximum 4 A
Depolama / Taşıma Sıcaklığı -40 ... +85 °C | -25 ... +85 °C
Designation, Serial diagnostic SD OUT
Rated insulation voltage (Uᵢ) 32 VDC
No-load supply current I0, typical 600 mA
Number of series-wiring of sensors 31
Current, Utilisation category DC-13 0.25 A
Integral system diagnostics, status Yes
Voltage, Utilisation category DC-13 24 VDC
Protection class (Operating resource) 2
Note (LED switching conditions display) Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Rated operating current (safety outputs) 250 mA
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -25 °C
Holding force FZh in accordance with EN ISO 14119 2,000 N
Safety Integrity Level (SIL), suitable for applications in 3
Tightening torque of the fastening screws for the housing cover 0.7 ... 1 Nm (Torx T10)
Tightening torque of the fastening screws for the housing cover, maximum 1 Nm
Tightening torque of the fastening screws for the housing cover, minimum 0.7 Nm