Note
All indications including the conductor ferrules. | for 2-channel use and with suitable logic unit. | at 20% ohmic contact load
Category
3 | 1
Cable Cross-Section
2 mm² ... 2 mm²(All indications including the conductor ferrules.)
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Cable entry
2 x M20 x 1,5
Mission time
20 Year(s)
Latching force
150 ... 400 N (adjustable)
Net Ağırlık
951 g
Bağlantı Tipi
rigid or flexible
Power to unlock
Yes
Gross weight
951 g
Housing Material
Aluminium
Contact material
Silver
Pollution degree
3
Min. cable cross-section
0.75 mm²
Max. cable cross-section
2.5 mm²
Note (Latch force)
adjustable
IP protection class
IP67
Ambient Temperature
-25 ... +50 °C
Performance level
c | d
Conventional thermal current
6 A
Working Principle
electromechanical
Switching element
Magnet: 1 NO Contact, 1 NC contact / Actuator: 1 NO contact, 1 NC contact
Switching principle
Slow action
Mechanical life (min.)
1,000,000
Utilisation category
AC-15 | DC-13
Maks. Sigorta Değeri
6 A gG D-fuse
Number of guard doors
1
Rated control voltage
110 VAC
Terminal connection
Screw terminals
Latching force, maximum
400 N
Latching force, minimum
150 N
Max. actuating speed
0.2 m/s
Switch-on time, maximum
100 s
Housing Coating Material
painted
Material of the actuator
Stainless steel (V2A)
Min. Ortam Sıcaklığı
-25 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
NC contact with positive break
Number of safety contacts
2 / 3 / 4
Maks. Ortam Sıcaklığı
+50 °C
Utilization Category AC-15
4 A | 230 VAC
Utilization Category DC-13
24 VDC | 1 A
Number of auxiliary contacts
1 / 2 / 3
Holding force Fmax, maximum
4,550 N
Max. switching frequency
2,000 /h
Note (Positive break force)
depending on the setting of the ball latch
Material of the latching bolt
Brass
Note (application conditions)
hinged safety guard | sliding safety guard
Positive break force, minimum
15 N
Rated impulse withstand voltage (Uimp)
4 kV
Number of actuating directions
1
B10D Normally-open contact (NO)
1,000,000
B10D Normally-closed contact (NC)
2,000,000
Rated insulation voltage (Uᵢ)
250 VAC
Required rated short-circuit current
1,000 A
Electrical power consumption, maximum
10 W
Coding level according to EN ISO 14119
Low
Holding force FZh in accordance with EN ISO 14119
3,500 N
Tightening torque of electrical connection, maximum
0.6 Nm
Tightening torque of electrical connection, minimum
0.4 Nm