Order No
101167210
Article Code
101167210
Certificates
cULus CCC
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
AZM 415-11/11ZPKF 110VAC
Product Description
- • IP Rating: IP65/IP67 | Weight: 915 g | Certification: cULus CCC
Standards
- • EN ISO 13849-1
Product Features
- • Adjustable ball latch to 400 N_x000D_
- • 2 switches in one enclosure_x000D_
- • Problem-free opening of stressed doors by means of bell-crank system_x000D_
- • Ex version available_x000D_
- • Manuel açma_x000D_
- • 141 mm x 100 mm x 56,5 mm_x000D_
- • Metal gövde_x000D_
- • Hatalı kilitlemeye karşı korumalı kilit_x000D_
- • Sağlam tasarım_x000D_
- • Uzun ömürlü_x000D_
- • 2 Kablo girişi M20 x 1,5_x000D_
- • Kesme-sıkıştırma terminali
Technical Specifications
Note
All belirtimler iletken end included.
Application Note
Slide-mounted guard cover hinged guard cover
Mission Time
20 Year(s)
Gross Weight
915 g
Housing Material
Aluminium
Contact Material
Silver
Min. Cable Cross-Section
2 x 0.75 mm²
Note (Relative Humidity)
Non-condensing, non-icing
Sensor Length
56.5 mm
Force to Open
Yes
Max. Cable Cross-Section
2 x 2.5 mm²
Manual Lock Release
Yes
IP Protection Class
IP65 IP67
Ambient Temperature
-25 ... +50 °C
Sensor Width
141 mm
Thermal Test Current
0.25
Operating Principle
Elektromekanik
Switching Element
NA contact, NK contact
Switching Principle
Slow hareket
Mechanical Life (min.)
1,000,000 Cycles
Sensor Height
100 mm
B10D NC Contact Value
2,000,000 Cycles
Min. Locking Force
150 N
Positive Opening Distance
5 mm
Terminal Connection
Threaded terminal block M20 x 1,5
Number of Protective Doors
1
Max. Actuation Speed
0.2 m/s
Max. Locking Force
400 N
Housing Coating Material
Painted
Rated Control Voltage
110 VAC
Note (Manual Lock Release)
Lock state M5 triangular switch with opening (accessory as available). Only power with opening prensipli birimlerde is used.
Number of Safety Contacts
2
Number of Actuation Directions
1
Utilization Category AC-15
0.16666666666787933
Utilization Category DC-13
0.041666666667879326
Min. Positive Opening Force
15 N
Number of Auxiliary Contacts
2
Impulse Withstand Voltage (Uimp)
4 kV
Holding Force FZh (EN ISO 14119)
3,500 N
Max. Electrical Power Consumption
10 W
Rated Insulation Voltage (Uᵢ)
250 VAC