Note
Electrical life on request. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
EPLAN
Yes
Mounting
Screws
CADENAS
Yes
Category
3 | 1
General note
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
Traceparts
Yes
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Power to lock
Yes
Mission time
20 Year(s)
Manual release
Yes
Net Ağırlık
650 g
Property class
8.8
Gross weight
650 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material
Silver
Protection class
III
Pollution degree
2
Scope of delivery
Slot cover for dust-proof covering of the opening not in use
Sensor length
48 mm
IP protection class
IP67 | IP65
Ambient Temperature
-25 ... +55 °C
Performance level
c | d
Sensor width
40 mm
Conventional thermal current
2 A
Working Principle
electromechanical
Switching element
Magnet: 1 NO contact / Actuator: 2 NC contacts
Switching principle
slow action, positive break NC contact
Mechanical life (min.)
1,000,000
Sensor height
204 mm
Magnet switch-on time
100 %
Maks. Sigorta Değeri
6 A gG D-fuse to DIN EN 60269-1
Positive break travel
5 mm
Rated control voltage
24 VDC
Terminal connection
Connector plug M12, 8-pole, A-coded
Latching force, approx.
50 N
Max. actuating speed
0.3 m/s
Min. Ortam Sıcaklığı
-25 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
galvanically separated contact bridges
Number of safety contacts
2 / 3 / 4
Maks. Ortam Sıcaklığı
+55 °C
Type of the fixing screws
4x M5
Integrated connection, M12
Yes
Utilization Category DC-13
24_2_FMAW00000001 | 24 VDC / 2 A / Connector 8-pole
Note (Mechanical lifetime)
from device version V2 (see type plate)
Relative humidity, maximum
93 %
Number of auxiliary contacts
1 / 2
Overvoltage category
II
Holding force Fmax, maximum
1,950 N
Max. switching frequency
1,000 /h
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Material of the latching bolt
Stainless steel (1.4104)
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Number of actuating directions
2
B10D Normally-open contact (NO)
1,000,000
Note, Utilisation category DC-13
Connector 8-pole
B10D Normally-closed contact (NC)
2,000,000
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Rated insulation voltage (Uᵢ)
30 V
Current, Utilisation category DC-13
2 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
8.5 W
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
Low
Material of the connector (electrical)
Metal film
Tightening torque of the fixing screws
1.3 ... 1.5 Nm
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Positive break force per NC contact, minimum
10 N
Tightening torque of the fixing screws, maximum
1.5 Nm
Tightening torque of the fixing screws, minimum
1.3 Nm
Holding force FZh in accordance with EN ISO 14119
1,500 N
Rated impulse withstand voltage, connector 8-pole
0.8 kV
Tightening torque of the fastening screws for the housing cover
0.5 Nm