Note
Torx T10 | Electrical life on request. | including conductor ferrules without plastic collar | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
EPLAN
Yes
Mounting
Screws
CADENAS
Yes
Category
3 | 1
General note
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
Traceparts
Yes
Cable Cross-Section
0.25 mm² ... 1.5 mm²
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Strip length
6 mm
Cable entry
3 x M20 x 1,5
Power to lock
Yes
Mission time
20 Year(s)
Manual release
Yes
Net Ağırlık
593 g
Property class
8.8
Gross weight
593 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material
Silver
Protection class
II
Pollution degree
2
Min. cable cross-section
0.25 mm²
Scope of delivery
Slot cover for dust-proof covering of the opening not in use | Actuator must be ordered separately.
Sensor length
48 mm
Max. cable cross-section
1.5 mm²
IP protection class
IP67 | IP65
Ambient Temperature
-25 ... +55 °C
Performance level
c | d
Sensor width
40 mm
Conventional thermal current
5A
Working Principle
electromechanical
Switching element
Magnet: 1 NO contact, 1 NC contact / Actuator: 2 NC contacts
Switching principle
slow action, positive break NC contact
Mechanical life (min.)
1,000,000
Sensor height
204 mm
Allowed type of cable
solid single-wire | solid multi-wire | flexible
Magnet switch-on time
100 %
Maks. Sigorta Değeri
6 A gG D-fuse to DIN EN 60269-1
Note (Manual release)
By means of M5 triangular key | For maintenance, installation, etc.
Positive break travel
5 mm
Rated control voltage
24 VDC
Terminal connection
Screw terminals
Latching force, approx.
50 N
Max. actuating speed
0.3 m/s
Tool for the connection
PZ 2
Min. Ortam Sıcaklığı
-25 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
galvanically separated contact bridges | with double break
Number of safety contacts
3 | 2 / 3 / 4
Maks. Ortam Sıcaklığı
+55 °C
Type of the fixing screws
4x M5
Utilization Category DC-13
24 VDC / 4 A / Screw terminals | 24_4
Note (Mechanical lifetime)
from device version V2 (see type plate)
Relative humidity, maximum
93 %
Number of auxiliary contacts
1 / 2 | 1
Overvoltage category
II
Holding force Fmax, maximum
1,950 N
Max. switching frequency
1,000 /h
ACE reference article number
11931077
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Material of the latching bolt
Stainless steel (1.4104)
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Rated impulse withstand voltage (Uimp)
4 kV
Number of actuating directions
2
B10D Normally-open contact (NO)
1,000,000
B10D Normally-closed contact (NC)
2,000,000
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Rated insulation voltage (Uᵢ)
300 V
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
4 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
8.5 W
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
Low
Tightening torque of the fixing screws
1.3 ... 1.5 Nm
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Positive break force per NC contact, minimum
10 N
Tightening torque of the fixing screws, maximum
1.5 Nm
Tightening torque of the fixing screws, minimum
1.3 Nm
Holding force FZh in accordance with EN ISO 14119
1,500 N
Tightening torque of electrical connection, maximum
0.8 Nm
Tightening torque of electrical connection, minimum
0.6 Nm
Tightening torque of the fastening screws for the housing cover
0.5 Nm