Note
Torx T10 | Electrical life on request. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Mounting
Screws
Category
3 | 1
Traceparts
Yes
Cable Cross-Section
0.75 mm² ... 1 mm²(All indications including the conductor ferrules.)
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Power to lock
Yes
Mission time
20 Year(s)
Latching force
5 / 30 N | 30 N
Manual release
Yes
Net Ağırlık
293 g
Gross weight
293 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material
Silver
Protection class
II
Pollution degree
3
Scope of delivery
Actuator must be ordered separately. | Slot sealing plugs
Sensor length
30 mm
Operating current
2,000 mA
IP protection class
IP67
Ambient Temperature
-25 ... +60 °C | -30 ... +60 °C
Performance level
c | d
Sensor width
90 mm
Conventional thermal current
2 A
Working Principle
electromechanical
Switching element
1 NO contact, 1 NC contacts
Switching principle
slow action, positive break NC contact
Mechanical life (min.)
1,000,000
Sensor height
79 mm
Magnet switch-on time
100 %
Maks. Sigorta Değeri
2 A gG D-fuse
Note (Manual release)
bottom
Positive break travel
11 mm
Rated control voltage
24 VAC/DC
Terminal connection
Connector plug M12, 8-pole, A-coded
Max. actuating speed
2 m/s
Increased latching force
Yes
Min. Ortam Sıcaklığı
-25 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges
Number of safety contacts
1 | 1 / 2 / 3 / 4
Maks. Ortam Sıcaklığı
+60 °C
Type of the fixing screws
2x M4
Integrated connection, M12
Yes
Utilization Category DC-13
24 VDC / 2 A / Connector 8-pole | 24_2
Number of auxiliary contacts
1 / 2 | 1
Overvoltage category
III
Holding force Fmax, maximum
1,300 N
Max. switching frequency
1,000 /h
Nominal Çalışma Voltajı
24 VDC
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Positive break force, minimum
8.5 N
Number of actuating directions
2
B10D Normally-open contact (NO)
1,000,000
Note, Utilisation category DC-13
Connector 8-pole
B10D Normally-closed contact (NC)
2,000,000
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C | -25 ... +85 °C
Rated insulation voltage (Uᵢ)
60 V
Current, Utilisation category DC-13
2 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
12 W
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
Low
Note (B10D Normally open contact (NO))
at 10% Ie and ohmic load
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Positive break force per NC contact, minimum
8.5 N
Holding force FZh in accordance with EN ISO 14119
1,000 N
Rated impulse withstand voltage, connector 8-pole
0.8 kV
Permissible installation altitude above sea level, maximum
2,000 m
Tightening torque of the fastening screws for the housing cover, maximum
1 Nm
Tightening torque of the fastening screws for the housing cover, minimum
0.7 Nm