Note
Electrical life on request. | at 10% Ie and ohmic load | for 2-channel use and with suitable logic unit.
Mounting
Screws
Category
3 | 1
Unlocking
pressing unlatcher (Escape release)
Cable Cross-Section
0.5 mm² ... 1.5 mm² (All indications including the conductor ferrules.)
Please note:
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Cable entry
2 x M20
Emergency exit
Yes
Mission time
20 Year(s)
Latching force
20 N
Manual release
Yes
Net Ağırlık
400 g
Frequency range
50 Hz | 60 Hz
Power to unlock
Yes
Gross weight
400 g
Housing Material
Glass-fibre, reinforced thermoplastic
Contact material
Silver
Protection class
II
Actuator rotation
0 °
Min. cable cross-section
0.5 mm², flexible | 0.5 mm², rigid
Scope of delivery
Actuator must be ordered separately.
Sensor length
41 mm
Max. cable cross-section
2.5 mm², flexible | 2.5 mm², rigid | 1.5 mm², flexible with conductor ferrule
Operating current
4,000 mA
IP protection class
IP65
Ambient Temperature
-25 ... +55 °C
Performance level
e | c | d
Sensor width
52 mm
Conventional thermal current
4 A
Working Principle
electromechanical
Switching element
Magnet: 2 NC contacts / Actuator: 1 NC contact
Switching principle
slow action, positive break NC contact
Mechanical life (min.)
1,000,000
Sensor height
178 mm
Magnet switch-on time
100 %
Maks. Sigorta Değeri
4 A gG D-fuse to DIN EN 60269-1
Note (Emergency exit)
Mounting only within the guarded area | For cases of danger
Note (Manual release)
front | For manual release using triangular key M3 (included in delivery) | For maintenance, installation, etc.
Positive break travel
3.5 mm
Rated control voltage
230 VAC
Interlocking principle
Power to unlock
Number of cable glands
2
Terminal connection
Screw terminals
Traceparts, product ID
33-22052019-077278
Max. actuating speed
0.3 m/s
Material of the actuator
Zinc-plated metal
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Performance Level)
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.
Note (Relative humidity)
non-condensing | non-icing
Note (Switching element)
galvanically separated contact bridges
Number of safety contacts
1 / 2 / 3 / 4 | 3
Maks. Ortam Sıcaklığı
+55 °C
Type of the fixing screws
2x M5
Utilization Category AC-15
230 VAC / 4 A / Screw terminals | 230_4
Utilization Category DC-13
24 VDC / 4 A / Screw terminals | 24_4 | 24 VDC / 4 A
Number of auxiliary contacts
1 / 2
Holding force Fmax, maximum
2,550 N
Max. switching frequency
1,200 /h
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms
Material of the latching bolt
Die-cast zinc
Note (application conditions)
removable guard | hinged safety guard | sliding safety guard
Positive break force, minimum
20 N
Rated impulse withstand voltage (Uimp)
4 kV
Number of actuating directions
4
B10D Normally-open contact (NO)
1,000,000
B10D Normally-closed contact (NC)
2,000,000
Rated insulation voltage (Uᵢ)
250 V
Current, Utilisation category AC-15
4 A
Current, Utilisation category DC-13
4 A
Required rated short-circuit current
1,000 A
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
Electrical power consumption, maximum
8.5 W
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
Low
Scope of delivery of mounting material
mounting plate MP190-VD
Holding force FZh in accordance with EN ISO 14119
1,950 N