Order No
103001416
Article Code
103001416
Certificates
TÜV cULus ECOLAB FCC IC UKCA ANATEL
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
AZM300B-I2-ST-SD2P
Product Description
- • IP Rating: IP66/IP67/IP69 | Voltage: 24 VDC | Weight: 550 g | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • Repeated individual coding with RFID technology_x000D_
- • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
- • Connector M12, 8-pole_x000D_
- • Açmak için güç gerekli_x000D_
- • Actuator monitored_x000D_
- • serial diagnostic output_x000D_
- • Hijyenik tasarım_x000D_
- • Protection class IP 69_x000D_
- • Suitable for mounting to profile systems_x000D_
- • Termoplastik gövde_x000D_
- • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
- • 3 different directions of actuation_x000D_
- • Kompakt tasarım_x000D_
- • Çalışma koşullarını gösteren 3 LED_x000D_
- • Menteşeli ve kızaklı koruyucular için uygun_x000D_
- • Series-wiring_x000D_
- • Manuel açma
Technical Specifications
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUTPUT series diagnostics output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
INPUT series diagnostics input
Coding
Individual coding, multiple teaching
Category
4
General Note
For doors flush with the door frame, the optional MP-AZ/AZM300-1 mounting plate can be used. For glass and Makrolon doors, the optional MS-AZ/AZM300-B1-1 mounting kit can be used.
PFD Value
4.50 x 10⁻⁵
PFH Value
5.20 x 10⁻¹⁰ /h
Impact Resistance
30 g / 11 ms
Latching
Yes
Mission Time
20 Year(s)
Serial Diagnostics
Yes
Series Connection
Yes
Gross Weight
550 g
Housing Material
Cam elyaf takviyeli termoplastik
Protection Class
III
Pollution Degree
3
Max. Relative Humidity
0.93
Note (Relative Humidity)
Non-condensing, non-icing
Sensor Length
120 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 150 Hz, amplitude 0.35 mm
Force to Open
Yes
Cable Capacitance
50 nF
Max. Risk Time
200 ms
Manual Lock Release
Yes
Operating Current
150 mA
24V Current Consumption
5 mA
IP Protection Class
IP66 IP67 IP69
Short-Circuit Detection
Yes
Ambient Temperature
+0 ... +60 °C
Performance Level
e
RFID Frequency Band
125 kHz
Sensor Width
87.5 mm
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
RFID
Actuator Monitored
Yes
Mechanical Life (min.)
1,000,000 Cycles
Note (Mechanical Life)
When used as a door stop: ≥ 50,000 cycles (door mass ≤ 5 kg and actuation speed ≤ 0.5 m/s)
Sensor Height
35 mm
Recommendation (Actuator)
AZ/AZM300-B1
Switching Thresholds
−3 V … 5 V (Low) 15 V … 30 V (High)
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection
Yes
Fixing Screw Type
2x M6
Terminal Connection
Connector M12, 8-pole, A-coded
Max. Leakage Current (Ir)
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Max. Installation Altitude
3,000 m
Max. Test Pulse Duration
0.5 ms
Max. Holding Force Fmax
1,500 N
Max. Ready Time
5,000 ms
Number of Actuation Directions
3
Current Utilization Cat. DC-12
0.25 A
Current Utilization Cat. DC-13
0.25 A
Min. Test Pulse Interval
100 ms
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance
2 mm
Overvoltage Category
III
Magnet Release Time
1
Rated Operating Voltage
24 VDC
Typical Test Pulse Interval
1000 ms
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Min. Fixing Screw Torque
6 Nm
Serial Diagnostics (SD) Definition
OUT
Guaranteed Opening Distance (ON) Sao
1 mm
Safety Inputs Definition
X1 and X2
Max. Voltage Drop (Ud)
2 V
Max. Fixing Screw Torque
7 Nm
Max. Transmitter RFID Output
-6 dBm
Magnet Control Definition
IN
Impulse Withstand Voltage (Uimp)
0.8 kV
Guaranteed Opening Distance (OFF) Sar
20 mm
Control Elements Design
Short devre resistant, p-type
Storage/Transport Temperature
-10 ... +90 °C
Integrated System Diagnostics Status
Yes
Locking Force Adjustment Position 1
25 N
Locking Force Adjustment Position 2
50 N
Coding Level (EN ISO 14119)
High
Max. Sensor Chain Length
200 m
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Holding Force FZh (EN ISO 14119)
1,150 N
Safety Outputs Definition
Y1 and Y2
Max. Electrical Fuse Rating
0.08333333333212067
Rated Insulation Voltage (Uᵢ)
32 VDC
Max. Switching Frequency (Approx.)
0.5 Hz
Required Rated Short-Circuit Current
100 A
Number of Safe Digital Outputs
2
External Wire and Device Fuse Rating
2 A gG
Magnet ON Peak Current Consumption
350 mA / 200 ms
ZVEI CB24I Sink Classification
C1 C2
ZVEI CB24I Source Classification
C2
Magnet ON Average Current Consumption
200 mA
Typical Idle Operating Current (I₀)
100 mA
Note (LED Switching Condition Indication)
Operating status: LED green / Fault / functional failure: LED red / Supply voltage UB: LED green
Max. Solenoid Lock-Actuator Angular Misalignment
2 °
Max. Response Time (Actuator to Safety Output Off)
100 ms
Max. Response Time (Safety Input to Safety Output Off)
1.5 ms