Mounting
central with threated flange
General note
The switch is to be mounted on iron with a non-magnetic layer of at least 20 mm.
Cable type
H03VV-F
Active area
front side
bias magnet
Yes
Cable sleeve
Yes
Shock resistance
30 g, on sine wave oscillation
Cable entry
PG9
Net Ağırlık
115 g
Bağlantı Tipi
Pre-wired cable
Length of cable
2 m
Gross weight
115 g
Housing Material
Glass-fibre, reinforced thermoplastic
Repeat accuracy R
0.3 mm
Scope of delivery
Actuator must be ordered separately.
Sensor length
103 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Diameter of sensor
13 mm
Wire cross-section
18 AWG | 0.75 mm²
width across flats
22 BK
Actuation Element
Magnet
IP protection class
IP67
Ambient Temperature
-28 ... +75 °C | -25 ... +75 °C
Working Principle
Magnetic drive
Switching element
Opener (NC)
Switching principle
Reed contacts, Non-contact principle
Mechanical life (min.)
1,000,000,000
Number of cable wires
2
Switching distance Sn
BP 10S = 5 mm | 2 x BP 22S = 15 ... 55 mm | 2 x BP 10S = 10 mm | BP 21S = 30 mm | 5 mm … 55 mm | BP 15S = 6 mm | 2 x BP 12S = 25 mm | 2 x BP 21S = 20 ... 55 mm | BP 34S = 20 mm | BP 31S = 15 mm | BP 11S = 5 mm | BP 22S = 25 mm | BP 20S = 15 mm | BP 12S = 10 mm | 2 x BP 11S = 15 mm
Resistant to vibration
30 g, on sine wave oscillation
Suitable for elevators
Yes
Max. actuating speed
18 m/s
Bounce duration, maximum
3 ms
Bounce duration, minimum
0.3 ms
Min. Ortam Sıcaklığı
-25 °C
Housing construction form
Cylinder smooth
Maks. Ortam Sıcaklığı
+75 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-2
Recommendation (actuator)
2x BP 10 S | 2x BP 12S | 2x BP 11 S | BP 20 S | BP 12 S | BP 31 S | BP 10 S | 2x BP 22 S | BP 22 S | BP 21 S | BP 11 S | BP 15 S | BP 34 S | BE 20 S | 2x BP 21 S
Bounce duration, typically
0.6 ms
Switching current, maximum
3 A
Switching voltage, maximum
250 VAC
Max. switching frequency
1,080,000 /h
Switching capacity, maximum
120 VA | 120 W
Material of the Cable mantle
PVC
Note (Switching distance Sn)
Actuating distance up to 55 mm depending on actuating magnet and version. The specified switching distances are applicable for the actuation of individually mounted components without ferromagnetic influence. A change of the distance, either positive or n
Switching frequency, maximum
300 Hz
Maximum switching time open (NC)
0.5 ms
Maximum switching time close (NO)
1.5 ms
Minimum switching time close (NO)
0.3 ms
Tightening torque of nuts, maximum
3 Nm
Number of NC (Normally Closed) Contacts
1
Recommendation (actuator, lift switchgear)
BP 10 | 2 x BP 10 | BP 15 | BP 34