Mounting
terminal block 7.5 mm
Latching
Yes
General note
The opening and closing functions depend on the direction of actuation, the actuating magnets and the polarity of the actuating magnets.
Cable type
LiYY
Active area
front side
Versions
Plug-in reed contact insert and base
Shock resistance
60 g, on sine wave oscillation
Net Ağırlık
40 g
Bağlantı Tipi
Pre-wired cable
Length of cable
1 m
Gross weight
40 g
Housing Material
Glass-fibre, reinforced thermoplastic
Scope of delivery
Actuator must be ordered separately.
Sensor length
16.5 mm
Wire cross-section
0.25 mm² | 23 AWG
Actuation direction
Lengthwise
IP protection class
IP40
Ambient Temperature
+0 ... +75 °C
Sensor width
40 mm
Working Principle
Magnetic drive
Switching principle
Reed contacts, Non-contact principle | Latching
Mechanical life (min.)
1,000,000,000
Sensor height
35 mm
Number of cable wires
2
Switching distance Sn
BP 15S = 5 … 22 mm | BP 20S = 3 ... 28 mm | BP 12S = 5 ... 27 mm | BP 11S = 4 ... 23 mm | BP 10S = 5 … 20 mm | BP 34S = 10 … 40 mm | BP 6S = 2 … 12 mm | BP 8S = 2 … 10 mm | 2 x BP 15S = 7 … 28 mm | 2 mm … 40 mm | 2 x BP 10S = 6 … 27 mm | BP 31S = 4 ... 30 mm
Resistant to vibration
60 g, on sine wave oscillation
Suitable for elevators
Yes
Max. actuating speed
18 m/s
Bounce duration, maximum
0.2 ms
Min. Ortam Sıcaklığı
+0 °C
Note (Switching element)
Plug-in reed contact insert
Housing construction form
Block
Maks. Ortam Sıcaklığı
+75 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-2
Recommendation (actuator)
BP 8 S | 2x BP 10 S | BP 20 S | BP 12 S | BP 31 S | BP 10 S | BP 6 S | BP 11 S | 2 x BP 15 S | BP 15 S | BP 34 S
Number of snap-in contacts
1
Switching current, maximum
1 A
Switching voltage, maximum
60 VDC | 60 VAC
Switching capacity, maximum
30 VA | 30 W
Material of the Cable mantle
PVC
Note (Switching distance Sn)
Actuating distance up to 40 mm depending on actuating magnet and version. The specified switching distances are applicable for the actuation of individually mounted components without ferromagnetic influence. A change of the distance, either positive or n
Maximum switching time open (NC)
0.07 ms
Maximum switching time close (NO)
2 ms
Scope of delivery of mounting material
1 x screw M4; 1 x angled sliding nut M4
Recommendation (actuator, lift switchgear)
2 x BP 15 | BP 10 | BP 6 | 2 x BP 10 | BP 15 | BP 34