Coding
Yes
CADENAS
Yes
General note
Contact symbols shown for the closed condition of the guard device.
Shock resistance
30 g / 11 ms
Mission time
20 Year(s)
Net Ağırlık
240 g
Bağlantı Tipi
cable
Length of cable
3 m
Gross weight
240 g
Housing Material
Glass-fibre, reinforced thermoplastic
Scope of delivery
Actuator must be ordered separately.
Sensor length
78 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Wire cross-section
18 AWG | 0.75 mm²
width across flats
36 BK
Actuation Element
Magnet
Direction of motion
Head-on to the active surface
IP protection class
IP67
Ambient Temperature
-25 ... +55 °C
Working Principle
Magnetic drive
Switching element
1 NC contact
Material of the nuts
Thermoplastic
Number of cable wires
4
Traceparts, product ID
33-22052019-077541
ISO thread of the sensor
M30
Min. Ortam Sıcaklığı
-25 °C
Duration of risk, maximum
50 ms
Number of safety contacts
1
Maks. Ortam Sıcaklığı
+55 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
BPS 303 | BPS 300 | BPS 303 SS
Utilization Category DC-13
24 VDC / 0.03 A
Mechanical Mounting Conditions
quasi-flush
Switching current, maximum
3 A
Switching voltage, maximum
250 VAC
Time to readiness, maximum
50 ms
Nominal Çalışma Voltajı
24 VDC
Switching capacity, maximum
750 W
Material of the Cable mantle
PVC
Switching frequency, maximum
5 Hz
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC
B10D Normally-closed contact (NC)
20,000,000
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Tightening torque of nuts, maximum
3 Nm
Assured switching distance "ON" Sao
8 mm
Current, Utilisation category DC-13
0.03 A
Integral system diagnostics, status
Yes
Safety monitoring module integrated
Yes
Voltage, Utilisation category DC-13
24 VDC
Assured switching distance "OFF" Sar
18 mm
Number of NC (Normally Closed) Contacts
1
Coding level according to EN ISO 14119
Low
Scope of delivery of mounting material
2x nuts M30 x 1.5
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Note (Integral System Diagnostics, status )
The LED is illuminated when the guard is closed.