BNS 333-01YR-M20
Order No 101169804
Article Code 101169804
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

BNS 333-01YR-M20

Product Description

  • • IP Rating: IP65 | Weight: 145 g | Contacts: 1 NC

Standards

  • • EN ISO 13849-1

Product Features

  • • 1 Kablo girişi M20 x 1,5_x000D_
  • • Termoplastik gövde_x000D_
  • • Uzun ömürlü_x000D_
  • • Suitable for food processing industry only in combination with BPS 303_x000D_
  • • Mekanik aşınma yok_x000D_
  • • 40 mm x 112 mm x 40 mm_x000D_
  • • Yanal hizasızlığa karşı duyarsız_x000D_
  • • Kirlenmeye karşı duyarsız_x000D_
  • • Wiring compartment_x000D_
  • • With integral evaluation

Technical Specifications

Note All belirtimler iletken end included.
Coding Yes
General Note Contact sembolleri guard of the device closed konumu for is shown.
Active Area right-hand side
Wire Cross-Section 15 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Gross Weight 145 g
Housing Material Cam elyaf takviyeli termoplastik
Min. Cable Cross-Section 2 x 0.75 mm²
Sensor Length 40 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Max. Cable Cross-Section 2 x 1.5 mm²
Max. Risk Time 50 ms
Actuation Element Magnet
IP Protection Class IP65
Ambient Temperature -25 ... +55 °C
Sensor Width 40 mm
Operating Principle Magnetic drive
Switching Element 1 NK contact
Sensor Height 112 mm
Recommendation (Actuator) BPS 300 BPS 303 BPS 303 SS
B10D NC Contact Value 20,000,000 Cycles
Terminal Connection Threaded terminal block M20 x 1,5
Number of Safety Contacts 1
Max. Switching Current 0.20833333333212067
Max. Ready Time 50 ms
Max. Switching Voltage 250 VAC
Mechanical Mounting Conditions Semi-recessed
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity 1,250 W
Guaranteed Opening Distance (ON) Sao 4 mm
Guaranteed Opening Distance (OFF) Sar 14 mm
Storage/Transport Temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) Low
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Integrated Safety Monitoring Module Yes
Max. Switching Frequency (Approx.) 5 Hz
Number of NC (Normally Closed) Contacts 1
Note (Integrated System Diagnostics Status) LED, guard when closed yanar.
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.