BNS 40S-12Z 3,0M
Order No 103000650
Article Code 103000650
Certificates cULus ECOLAB
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

BNS 40S-12Z 3,0M

Product Description

  • • IP Rating: IP69 | Weight: 250 g | Cable: 3 m | Certification: cULus ECOLAB | Contacts: 2 NC, 1 NO

Standards

  • • EN ISO 13849-1

Product Features

  • • Stainless steel enclosure_x000D_
  • • Cable connection suitable for the food industry_x000D_
  • • Gizli montaj mümkün_x000D_
  • • 88 mm x 27 mm x 14,5 mm_x000D_
  • • Uzun ömürlü_x000D_
  • • Mekanik aşınma yok_x000D_
  • • Kirlenmeye karşı duyarsız_x000D_
  • • Yanal hizasızlığa karşı duyarsız_x000D_
  • • Suitable for food processing industry

Technical Specifications

Coding Yes
General Note Contact sembolleri guard of the device closed condition for is shown. LED'li/LED'siz of the versions contact configuration is the same.
Cable Type LiYY
Wire Cross-Section 23 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 3 m
Gross Weight 250 g
Housing Material Stainless steel (V4A)
Sensor Length 14 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Number of Cable Wires 6
Actuation Element Magnet
IP Protection Class IP69
Ambient Temperature -25 ... +80 °C
Sensor Width 88 mm
Operating Principle Magnetic drive
Switching Element 1 NA contact, 2 NK contact
Switching Principle Reed contacts, non-contact prensip
Sensor Height 27 mm
Recommendation (Actuator) BPS 40S-2 BPS 40S-1-C BPS 40S-2-C BPS 40S-1
Terminal Connection Cable
Connection Diagram Note S21-S22 contact safety devresine integrated must be.
B10D NC/NA Contact Value 25,000,000 Cycles
Cable Sheath Material PVC
Max. Switching Current 0.25 A
Mechanical Mounting Conditions Embedded not
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Hidden Threaded Holes at the Rear No
Max. Switching Capacity 3 W
Guaranteed Opening Distance (ON) Sao 8 mm
Guaranteed Opening Distance (OFF) Sar 18 mm
Storage/Transport Temperature -25 ... +80 °C
Coding Level (EN ISO 14119) Low
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Precondition Evaluation Unit Yes
Max. Switching Frequency (Approx.) 5 Hz
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 2
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.