CSP 11-34-D-M-ST
Order No 101208004
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

CSP 11-34-D-M-ST

CSP 11-34-D-M-ST — Schmersal product. Key specifications: Working Principle: inductive; Housing Material: Glass-fibre, reinforced thermoplastic; IP protection class: IP67 | IP65; Ambient Temperature: -25 ... +70 °C; Sensor length: 27 mm. Article number: 101208004. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP65
  • • Ağırlık: 111 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN ISO 13849-1

Product Features

  • • 1 x connector plug M12, 8-pole
  • • Actuation from side
  • • without On-site acknowledgment
  • • NOTICE: Not available! (Replacement: RSS 36 I)
  • • Thermoplastic enclosure
  • • Electronic contact-free, coded system
  • • Tampering protection by paired coding of sensor and actuator
  • • Misaligned actuation possible
  • • High repeat accuracy of the switching points
  • • Max. length of the sensor chain 200 m
  • • 2 short-circuit proof PNP safety outputs
  • • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Technical Specifications

PIN 1 1A1 Ue: (1)
PIN 2 X1 Safety input 1
PIN 3 A2 GND
PIN 4 Y1 Safety output 1
PIN 5 OUT Diagnostic output OUT
PIN 6 X2 Safety input 2
PIN 7 Y2 Safety output 2
PIN 8 IN without function
Category 4
General note Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circu | Coding of safety sensor and actuator: To activate the safety function (coding) of the CSP 34 for the first time, the associated actuator must be brought into the detection area of the switched on safety sensor. The automatic learn process of the actuator
PFH value 3.60 x 10⁻⁹ /h
Cascadable Yes
EMC rating IEC 61000-6-2
Active area Glass-fibre, reinforced thermoplastic | lateral
Voltage type DC
Shock resistance 30 g / 11 ms
Mission time 20 Year(s)
Net Ağırlık 111 g
Number of LEDs 3
Bağlantı Tipi Connector plug M12, 8-pole
Sensor topology Sensor for series wiring
Actuating panels lateral
Gross weight 111 g
Current derating Ambient temperature -25°C … +65°C: ≤ 0.25 A | Ambient temperature -25°C … +70°C: ≤ 0.1 A
Housing Material Glass-fibre, reinforced thermoplastic
Protection class II
Safety functions Yes
Diagnostic output Yes
Pollution degree 3
Operating voltage 24 VDC -15 % / +10 %
Repeat accuracy R 0.5 mm
Scope of delivery Actuator must be ordered separately.
Sensor length 27 mm
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Operating current 600 mA | 50 mA
IP protection class IP67 | IP65
Ambient Temperature -25 ... +70 °C
Performance level e
Sensor width 35 mm
Working Principle inductive
Sensor height 108.2 mm
Utilisation category DC-12
Interfering radiation IEC 61000-6-4
Reaction time, maximum 30 ms
Cross-circuit detection Yes
Short circuit detection Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Note (Repeat accuracy R) Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 30 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 8 mm.
Switch distance, typical 11 mm
Voltage drop Ud, maximum 0.5 V | 5 V
Duration of risk, maximum 60 ms
Housing construction form Block
Maks. Ortam Sıcaklığı +70 °C
Note (switching distance) All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator) CSP 34-S-1
Design of control elements p-type
Utilization Category DC-13 24 VDC / 0.25 A | 0.05 A | 24 VDC | 24 VDC / 0.05 A
Mechanical Mounting Conditions not flush
Utilisation category DC-12 24 VDC | 0.05 A | 24 VDC / 0.05 A | 24 VDC / 0.25 A | 24_0.05 | 24_0.25
Overvoltage category 3 | III
Leakage current Ir, maximum 0.5 mA
Nominal Çalışma Voltajı 24 VDC
Switching frequency, approx. 3 Hz
Recommended safety switchgear SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Rated impulse withstand voltage (Uimp) 0.8 kV
Electrical fuse rating, maximum 2 A
Rated operating voltage, maximum 26.4 VDC
Rated operating voltage, minimum 20.4 VDC
Depolama / Taşıma Sıcaklığı -25 ... +85 °C | -40 ... +85 °C
Rated insulation voltage (Uᵢ) 32 VAC/DC
Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical 100 mA
Number of series-wiring of sensors 31
Assured switching distance "ON" Sao 8 mm
Current, Utilisation category DC-12 0.05 A | 0.25 A
Current, Utilisation category DC-13 0.25 A
Required rated short-circuit current 100A
Integral system diagnostics, status Yes
Note (Electrical data, Fuse rating) (Circuit breaker)
Number of fail-safe digital outputs 2
Voltage, Utilisation category DC-12 24 VDC
Voltage, Utilisation category DC-13 24 VDC
Absicherung des Sicherheitsausganges short-circuit proof
Assured switching distance "OFF" Sar 15 mm
Protection class (Operating resource) 2
Hysteresis (Switching distance), maximum 1.5 mm
Rated operating current (safety outputs) 250 mA
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -25 °C
Output current, (fail-safe output), maximum 0.25 A
Number of semi-conductor outputs with signaling function 1
Safety Integrity Level (SIL), suitable for applications in 3

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3