EPLAN
Yes
PIN 1
A1 Ue Brown
PIN 2
X1 Safety input 1 White
PIN 3
A2 GND Blue
PIN 4
Y1 Safety output 1 Black
PIN 5
SD serial diagnostic output: Grey
PIN 6
X2 Safety input 2 violet
PIN 7
Y2 Safety output 2 red
PIN 8
IN serial diagnostic input Pink
Category
4
General note
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circu
PFH value
3.60 x 10⁻⁹ /h
Cable type
LiYY
Cascadable
Yes
EMC rating
IEC 61000-6-2
Traceparts
Yes
Active area
front side | Glass-fibre, reinforced thermoplastic
Cable Cross-Section
8 mm²
Lead colours
Black
Shock resistance
30 g / 11 ms
Mission time
20 Year(s)
Net Ağırlık
300 g
Number of LEDs
3
Bağlantı Tipi
Cable (Y-UL 2517), 8-pole
Length of cable
1 m
Sensor topology
Sensor for series wiring
Actuating panels
from head
Gross weight
300 g
Current derating
Ambient temperature 70°C: ≤ 2 A | Ambient temperature up to 60°C: ≤ 3.15 A | Ambient temperature up to 45°C: ≤ 4 A | Ambient temperature 65°C: ≤ 2.5 A
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
II
Safety functions
Yes
Diagnostic output
Yes
Pollution degree
3
Operation current
150 mA
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensor length
35 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Max. cable cross-section
8 x 0.35 mm²
Serial diagnostics
Yes
Wire cross-section
22 AWG
Wiring capacitance
50 nF
Operating current
600 mA
IP protection class
IP67 | IP65
Ambient Temperature
-25 ... +70 °C
Performance level
e
Sensor width
27 mm
Working Principle
inductive
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
108.2 mm
Utilisation category
DC-12 | DC-13
Interfering radiation
IEC 61000-6-4
Electrical fuse rating
short-circuit proof
Reaction time, maximum
30 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Repeat accuracy R)
Axial offset: the front face allows for an axial misalignment (z) of max. ± 8 mm (see figure: operating principle).
Voltage drop Ud, maximum
0.5 V | 5 V
Duration of risk, maximum
60 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+70 °C
Design of control elements
short-circuit proof, p-type | p-type
Utilization Category DC-13
24 VDC / 0.25 A | 0.05 A | 24 VDC | 24_0.05 | 24 VDC / 0.05 A
Mechanical Mounting Conditions
not flush
Utilisation category DC-12
24 VDC | 0.05 A | 24 VDC / 0.25 A | 24 VDC / 0.05 A | 24_0.05 | 24_0.25
Overvoltage category
3 | III
Leakage current Ir, maximum
0.5 mA
Switching distance actuator
Actuator CST 180-1 / CST 180-2: 12 mm (typical switch distance Sn) | Actuator CST 34-V-1: 10 mm (ensured switch distance ON Sao) | Actuator CST 180-1 / CST 180-2: 16 mm (ensured switch distance OFF Sar) | Actuator CST 34-S-1 / CST 34-S-3: 15 mm (typical switch distance Sn) | Actuator CST 34-S-1 / CST 34-S-3:: 18 mm (ensured switch distance OFF Sar) | Actuator CST 180-1 / CST 180-2: 10 mm (ensured switch distance ON Sao) | Actuator CST 34-S-2: 10 mm (typical switch distance Sn) | Actuator CST 34-V-1: 12 mm (typical switch distance Sn) | Actuator CST 34-S-2: 8 mm (ensured switch distance ON Sao) | Actuator CST 34-S-2: 16 mm (ensured switch distance OFF Sar) | Actuator CST 34-V-1: 15 mm (ensured switch distance OFF Sar) | Actuator CST 34-S-1 / CST 34-S-3: 13 mm (ensured switch distance ON Sao)
Switching frequency, approx.
3 Hz
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Rated impulse withstand voltage (Uimp)
0.8 kV
Absicherung des Diagnoseausganges
short-circuit proof
Depolama / Taşıma Sıcaklığı
-25 ... +85 °C | -40 ... +85 °C
Designation, Serial diagnostic SD
OUT
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Number of series-wiring of sensors
31
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
short-circuit proof
Protection class (Operating resource)
2
Hysteresis (Switching distance), maximum
1.5 mm
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.25 A
Number of semi-conductor outputs with signaling function
1
Safety Integrity Level (SIL), suitable for applications in
3