Schmersal CSS 12-34-V-SD-M-ST
Order No 101181067
Certificates cULus
Schmersal System Solutions Series Diagnostic Systems

CSS 12-34-V-SD-M-ST Series Diagnostic Systems

Schmersal CSS 12-34-V-SD-M-ST features inductive working principle, cam elyaf takviyeli termoplastik housing material, IP65 IP67 protection class and -25 ... +70 °C ambient temperature.

Series: Sensors →

Product Description

  • • IP Rating: IP65/IP67
  • • Weight: 140 g
  • • Certification: cULus
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 60947-5-3
  • • EN IEC 61508

Product Features

  • • 1 x connector plug M12, 8-pole
  • • Actuation from the top
  • • serial diagnostic output
  • • Max. 31 sensors can be wired in series.
  • • Thermoplastic housing
  • • Electronic non-contact coded system
  • • Misaligned actuation possible
  • • 27 mm x 108.2 mm x 35 mm
  • • High repeat accuracy of the switching points
  • • Max. length of the sensor chain 200 m
  • • 2 short-circuit proof PNP safety outputs
  • • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Technical Specifications

PIN 1 1A1 Ue: (1)
PIN 2 X1 Safety input 1
PIN 3 A2 GND
PIN 4 Y1 Safety output 1
PIN 5 SD serial diagnostic output
PIN 6 X2 Safety input 2
PIN 7 Y2 Safety output 2
PIN 8 INPUT serial diagnostic input
Category 4
General note Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate max. ... of the sensor outputs.
Active Area front side
Wire Cross-Section 22 AWG
PFH value 3.60 x 10⁻⁹ /h
Number of LEDs 3
Shock resistance 30 g / 11 ms
EMC Class IEC 61000-6-2
Mission time 20 Year(s)
Max. Hysteresis 1.5 mm
Serial Diagnostics Yes
Gross weight 140 g
Housing Material Glass-fibre reinforced thermoplastic
Protection Class II
Pollution degree 3
Radiated Interference IEC 61000-6-4
Sensor length 35 mm
Scope of delivery Actuator must be ordered separately.
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Cable Capacitance 50 nF
Max. Risk Time 60 ms
Sensor Topology Sensor for series connection
Operating current 150 mA
IP protection class IP65 IP67
Short-Circuit Detection Yes
Max. reaction time 30 ms
Ambient Temperature -25 ... +70 °C
Performance level e
Sensor width 27 mm
Working Principle inductive
Actuation Panels from head
Cascadable Yes
Housing Design Block
Sensor height 108.2 mm
Recommendation (Actuator) CST 34-V-1 CST 34-S-2 CST 34-S-3 CST 180-1 CST 180-2
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output Yes
Cross-Circuit Detection Yes
Terminal connection M12 connector plug, 8-pole
Max. Leakage Current (Ir) 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Utilization Category DC-13 0.05 A
Mechanical Mounting Conditions Non-flush
Note (Repeat Accuracy R) Axial offset: the front face allows for an axial misalignment (z) of max. ± 8 mm (see figure: operating principle).
Overvoltage category III
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Serial Diagnostics (SD) Definition OUT
Max. Voltage Drop (Ud) 5 V
Number of Sensors Connected in Series 31
Rated impulse withstand voltage (Uimp) 0.8 kV
Control Elements Design Short-circuit proof, p-type
Actuator Switching Distance Actuator CST 34-V-1: 12 mm (typical switch distance Sn) Actuator CST 34-V-1: 10 mm (ensured switch distance ON Sao) Actuator CST 34-V-1: 15 mm (ensured switch distance OFF Sar) Actuator CST 34-S-1 / CST 34-S-3: 15 mm (typical switch distance Sn) Actuator CST 34-S-1 / CST 34-S-3: 13 mm (ensured switch distance ON Sao) Actuator CST 34-S-1 / CST 34-S-3:: 18 mm (ensured switch distance OFF Sar) Actuator CST 34-S-2: 10 mm (typical switch distance Sn) Actuator CST 34-S-2: 8 mm (ensured switch distance ON Sao) Actuator CST 34-S-2: 16 mm (ensured switch distance OFF Sar) Actuator CST 180-1 / CST 180-2: 12 mm (typical switch distance Sn) Actuator CST 180-1 / CST 180-2: 10 mm (ensured switch distance ON Sao) Actuator CST 180-1 / CST 180-2: 16 mm (ensured switch distance OFF Sar)
Storage/transport temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Approximate Switching Frequency 3 Hz
Rated insulation voltage (Uᵢ) 32 VDC
Required rated short-circuit current 100A
Number of Safe Digital Outputs 2
Note (Electrical Data Fuse Rating) (Circuit breaker)
Typical Idle Operating Current (I₀) 100 mA
Max. Output Current (Safe Output) 0.25 A
Number of Semiconductor Outputs with Signal Function 1
Rated Operating Current (Safety Outputs) 250 mA
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3